使用低倍光学显微镜对不锈钢表面细菌细胞的光学检测
Optical detection of bacterial cells on stainless-steel surface with a low-magnification light microscope
AI总结:
本研究开发了一种基于3-MPBA修饰镀金芯片的低倍显微镜细菌检测方法,结合拭子采样可检测不锈钢表面细菌,成本低、耗时短,在低资源场景下的表面污染防控中极具应用潜力。
摘要:
快速且经济高效的表面细菌细胞检测方法对于从食品安全、临床卫生、药品质量等多方面保障公众健康至关重要。本文中,我们首先建立了一种基于镀金芯片的光学检测方法,该芯片表面修饰有3-巯基苯硼酸(3-MPBA)以捕获细菌细胞,可通过标准光学显微镜在低倍(10倍)物镜下实现细菌细胞的检测与定量。随后,我们将所开发的光学检测方法与拭子采样相结合,实现了对不锈钢表面负载细菌细胞的检测。\n以肠炎沙门氏菌(Salmonella enterica,SE1045)和大肠杆菌(Escherichia coli)为模式细菌细胞,在优化条件下,当菌液浓度为Log 3 CFU/mL时,我们对SE1045细胞的捕获效率最高可达76.0%,对大肠杆菌细胞的捕获效率最高可达81.1%。我们的检测方法显示,细菌细胞浓度与图像中的细胞计数之间具有良好的线性关系,SE1045和大肠杆菌细胞的检测限(LOD)均为Log 3 CFU/mL。通过热处理可进一步提高大肠杆菌细胞的检测灵敏度,使检测限可低至Log 2 CFU/mL。\n此外,该方法结合拭子采集后已成功应用于不锈钢表面细菌污染的评估,约70%的回收率表明其在表面清洁度评估方面具有应用前景。整个过程可在约2小时内完成,每个样本的检测成本仅为2美元。考虑到一台标准光学显微镜的成本约为250美元,我们开发的方法在资源匮乏地区的表面细菌污染控制实际工业应用中展现出巨大潜力。
英文摘要:
A Rapid and cost-effective method for detecting bacterial cells on surfaces is critical to protect public health from various aspects, including food safety, clinical hygiene, and pharmacy quality. Herein, we first established an optical detection method based on a gold chip coating with 3-mercaptophenylboronic acid (3-MPBA) to capture bacterial cells, which allows for the detection and quantification of bacterial cells with a standard light microscope under low-magnification (10 fold) objective lens. Then, integrating the developed optical detection method with swab sampling to achieve to detect bacterial cells loading on stainless-steel surfaces. Using Salmonella enterica (SE1045) and Escherichia coli as model bacterial cells, we achieved a capture efficiency of up to 76.0 % for SE1045 cells and 81.1 % for E. coli cells at Log 3 CFU/mL upon the optimized conditions. Our assay showed good linear relationship between the concentrations of bacterial cells with the cell counting in images with the limit of detection (LOD) of Log 3 CFU/mL for both SE1045 and E. coli cells. A further increase in sensitivity in detecting E. coli cells was achieved through a heat treatment, enabling the LOD to be pushed as low as Log 2 CFU/mL. Furthermore, successful application was observed in assessing bacterial contamination on stainless-steel surface following integrating with swab collection, achieving a recovery rate of approximately 70 % suggests future prospects for evaluating the cleanliness of surfaces. The entire process was completed within around 2 hours, with a cost of merely 2 dollars per sample. Given a standard light microscope cost around 250 dollars, our developed method has shown great potential in practical industrial applications for bacterial contamination control on surfaces in low-resource settings.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。