本文比较了半自动与基于神经网络的自动分割对腹主动脉瘤壁应力计算的影响,发现两者结果差异不显著,为从CT到应力评估的全自动生物力学分析流程奠定基础。

摘要:

背景:为了在腹主动脉瘤(AAA)中临床采用基于应力的破裂风险估计,从临床成像到生物力学应力计算的完全自动化流程至关重要。为此,我们研究了基于人工智能的图像分割方法对AAA壁应力计算结果的影响。我们比较了由经典半自动分割获得的几何模型与由自动化神经网络分割获得的几何模型计算出的壁应力分布和大小。方法:由一名分析人员对16幅不同的AAA增强计算机断层扫描(CT)图像进行半自动分割,根据图像质量的不同,每位患者需要15至40分钟的人工操作时间。同样的图像使用NUREA公司(https://www.nurea-soft.com/)基于人工智能(AI)算法开发的PRAEVAorta2商业软件进行自动分割,并使用内部MATLAB代码进行自动后处理,每位患者仅需1-2分钟的计算机处理时间。动脉瘤壁应力计算使用BioPARR软件(https://bioparr.mech.uwa.edu.au/)自动完成。结果:与经典半自动分割相比,基于神经网络的自动分割得到了等效的应力分布,以及略高的峰值和99百分位最大主应力值。然而,我们的统计分析表明,使用两种分割方法获得的AAA壁应力差异在统计学上不显著,并且完全处于分析人员间和分析人员内变异性的典型范围内。结论:我们的发现是迈向AAA生物力学分析全自动化流程的一个基石,该流程从CT扫描开始,以壁应力评估结束。

英文摘要:

Background: For the clinical adoption of stress-based rupture risk estimation in abdominal aortic aneurysms (AAAs), a fully automated pipeline, from clinical imaging to biomechanical stress computation, is essential. To this end, we investigated the impact of AI-based image segmentation methods on stress computation results in the walls of AAAs. We compared wall stress distributions and magnitudes calculated from geometry models obtained from classical semi-automated segmentation versus automated neural network-based segmentation. Method: 16 different AAA contrast-enhanced computed tomography (CT) images were semi-automatically segmented by an analyst, taking between 15 and 40 minutes of human effort per patient, depending on image quality. The same images were automatically segmented using PRAEVAorta2 commercial software by NUREA (https://www.nurea-soft.com/), developed based on artificial intelligence (AI) algorithms, and automatically post-processed with an in-house MATLAB code, requiring only 1-2 minutes of computer time per patient. Aneurysm wall stress calculations were automatically performed using the BioPARR software (https://bioparr.mech.uwa.edu.au/). Results: Compared to the classical semi-automated segmentation, the automatic neural network-based segmentation leads to equivalent stress distributions, and slightly higher peak and 99th percentile maximum principal stress values. However, our statistical analysis indicated that the differences in AAA wall stress obtained using the two segmentation methods are not statistically significant and fall well within the typical range of inter-analyst and intra-analyst variability. Conclusions: Our findings are a steppingstone toward a fully automated pipeline for biomechanical analysis of AAAs, starting with CT scans and concluding with wall stress assessment.