基于超精密切削的近红外大视场积分视场单元研制

Development of a near-infrared wide-field integral field unit by ultra-precision diamond cutting

Kosuke Kushibiki, Shinobu Ozaki, Masahiro Takeda, Takuya Hosobata, Yutaka Yamagata, Shinya Morita, Toshihiro Tsuzuki, Keiichi Nakagawa, Takao Saiki, Yutaka Ohta… 展开作者

Kosuke Kushibiki, Shinobu Ozaki, Masahiro Takeda, Takuya Hosobata, Yutaka Yamagata, Shinya Morita, Toshihiro Tsuzuki, Keiichi Nakagawa, Takao Saiki, Yutaka Ohtake, Kenji Mitsui, Hirofumi Okita, Yutaro Kitagawa, Yukihiro Kono, Kentaro Motohara, Hidenori Takahashi, Masahiro Konishi, Natsuko Kato, Shuhei Koyama, Nuo Chen

AI总结:

针对现有近红外积分视场光谱仪视场偏小的问题,采用超精密切削技术研制出大视场像切片型近红外积分视场单元,像质与通量符合设计要求,基本满足指标。

摘要:

积分视场光谱学(Integral Field Spectroscopy,IFS)是一种可在单次曝光中获取特定视场(field of view,FoV)内空间分辨光谱的观测方法。近年来,近红外IFS在观测受尘埃强消光或高红移天体方面的重要性日益凸显。现有近红外IFS仪器的一个局限是其视场相对较小,不足100角秒²,远小于光学仪器的视场。为此,我们通过将切片宽度匹配至0.4角秒的典型视宁度尺寸,研制出一款工作在近红外波段(0.9-2.5μm)、视场达13.5×10.4角秒²的像切片型积分视场单元(integral field unit,IFU)。该IFU采用紧凑光学设计,利用离轴椭球镜减小像差。复杂光学元件通过超精密切削机床加工,实现了均方根表面粗糙度小于10nm、峰谷形状误差小于300nm的精度,超精密加工还可简化装调流程。在轨性能评估证实,该IFU的像质和通量均符合设计要求。综上,我们利用超精密切削技术成功研制出一款紧凑型IFU,基本满足各项指标要求。

英文摘要:

Integral Field Spectroscopy (IFS) is an observational method to obtain spatially resolved spectra over a specific field of view (FoV) in a single exposure. In recent years, near-infrared IFS has gained importance in observing objects with strong dust attenuation or at high redshift. One limitation of existing near-infrared IFS instruments is their relatively small FoV, less than 100 arcsec$^2$, compared to optical instruments. Therefore, we have developed a near-infrared (0.9-2.5 $\mathrmμ$m) image-slicer type integral field unit (IFU) with a larger FoV of 13.5 $\times$ 10.4 arcsec$^2$ by matching a slice width to a typical seeing size of 0.4 arcsec. The IFU has a compact optical design utilizing off-axis ellipsoidal mirrors to reduce aberrations. Complex optical elements were fabricated using an ultra-precision cutting machine to achieve RMS surface roughness of less than 10 nm and a P-V shape error of less than 300 nm. The ultra-precision machining can also simplify alignment procedures. The on-sky performance evaluation confirmed that the image quality and the throughput of the IFU were as designed. In conclusion, we have successfully developed a compact IFU utilizing an ultra-precision cutting technique, almost fulfilling the requirements.