使用 Hanle 阶梯光栅光谱仪(HESP)进行彗星光学光谱观测
Optical spectroscopy of comets using Hanle Echelle Spectrograph (HESP)
AI总结:
研究利用 HCT 上的 HESP 获取四颗彗星 R=30000 与 60000 的光学光谱,识别分子转动谱线并分析 [OI] G/R 比、NH₂ 正仲比及氨自旋温度。
摘要:
观测彗星光学光谱中的振动/转动谱线需要高分辨率光谱学,否则这些谱线会表现为混合特征。为实现这一目标,我们利用安装在印度 2 米 Himalayan Chandra Telescope(HCT)上的 Hanle Echelle Spectrograph(HESP),获得了多颗彗星的中分辨率和高分辨率光谱,分辨率 R(λ/Δλ)分别为 30000 和 60000,目标包括 C/2015 V2(Johnson)、46P/Wirtanen、41P/Tuttle-Giacobini-Kresák 和 38P/Stephan-Oterma。这些光谱有效覆盖 3700–10,000 Å 波长范围,使我们能够探测各种振动谱带和谱带序列,从而识别彗星分子发射中的转动谱线。我们还能够将彗星氧谱线与地球大气谱线分离,并分析若干彗星中禁戒氧 [OI] 的绿红比(G/R)。对于 C/2015 V2、46P 和 41P 彗星,计算得到的 G/R 比分别为 0.04±0.01、0.04±0.01 和 0.08±0.02,表明 H₂O 是氧发射的主要来源。值得注意的是,在指向距 46P 光心 1000 km 位置的第二光纤中,G/R 比降至第一光纤观测值的一半以下,表明内彗发中存在淬灭效应。我们还测得 46P 彗星的 NH₂ 正仲比约为 3.41±0.05,并推导出氨比值为 1.21±0.03,对应约 26 K 的自旋温度。基于这些结果,我们展示了利用中、高分辨率光学光谱对来自不同彗星储库的四颗彗星开展研究的成果,并强调该仪器在未来彗星研究中的能力。
英文摘要:
Observing the vibrational/rotational lines in a comet's optical spectrum requires high-resolution spectroscopy, as they are otherwise seen as a blended feature. To achieve this, we have obtained medium and high-resolution (R ($λ/Δλ$) = 30000 and 60000) spectra of several comets, including C/2015 V2 (Johnson), 46P/Wirtanen, 41P/Tuttle-Giacobini-Kresák and 38P/Stephan-Oterma, using the Hanle Echelle Spectrograph (HESP) mounted on the 2-m Himalayan Chandra Telescope (HCT) in India. The spectra effectively cover the wavelength range 3700 - 10,000 Å, allowing us to probe the various vibrational bands and band sequences to identify the rotational lines in the cometary molecular emission. We were also able to separate the cometary Oxygen lines from the telluric lines and analyse the green-to-red (G/R) forbidden oxygen [OI] ratios in a few comets. For comets C/2015 V2, 46P, and 41P, the computed G/R ratios, 0.04$\pm$0.01, 0.04$\pm$0.01, and 0.08$\pm$0.02 respectively, point to H$_2$O being a major source of Oxygen emissions. Notably, in the second fibre pointing at a location 1000 km away from the photocenter of comet 46P, the G/R ratio reduced by more than half the value observed in the first fibre, indicating the effects of quenching within the inner coma. We also measured the NH$_2$ ortho-to-para ratio of comet 46P to be about 3.41$\pm$0.05 and derived an ammonia ratio of 1.21$\pm$0.03 corresponding to a spin temperature of $\sim$26 K. With these, we present the results of the study of four comets from different cometary reservoirs using medium and high-resolution optical spectroscopy, emphasising the capabilities of the instrument for future cometary studies.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。