在振动台试验中监测中等延性缩尺RC框架的抗震性能

Monitoring the Seismic Behavior of a Scaled RC Frame with Intermediate Ductility in a Shaking Table Test

Mohammad Vasef, Mohammad Sadegh Marefat, Sina Shid-Moosavi, Peng "Patrick" Sun

AI总结:

本文通过1/2.78缩尺三层RC IMF振动台试验,采用递增PGA的Sarpol-E-Zahab地震记录,并对比传统传感器与计算机视觉监测结构响应。

摘要:

钢筋混凝土(RC)中等抗弯框架(IMF)是结构中常用的抗震抗力体系之一。尽管根据ASCE 7-10,在高地震危险区不允许使用IMF,但伊朗2800抗震标准和新西兰抗震规范均允许使用。本研究通过对依据ACI318-19规定设计的二维RC结构模型进行振动台试验,研究钢筋混凝土IMF在地震激励下的抗震性能。由于振动台尺寸限制,框架制作选用1/2.78的缩尺系数。所构建模型为三层,每层层高115 cm,梁净长151 cm,柱和梁的截面尺寸分别为11×11 cm和12×11 cm。整个结构由长173 cm、宽52 cm、深22 cm的基础支承。柱和梁采用直径8 mm的带肋纵向钢筋以及直径6 mm的箍筋配筋。试验分阶段进行,逐级增大峰值地面加速度(PGA),直至框架破坏。试验采用Sarpol-E-Zahab地震记录。试验过程中同时使用传统传感器和基于视觉的传感器监测结构响应(例如位移、纵向钢筋应变、裂缝扩展和加速度)。作为一项对比研究,传统传感器和计算机视觉技术均被用于监测该缩尺RC框架结构的健康状态并分析其结构动力学特性。

英文摘要:

One of the commonly used seismic force-resisting systems in structures is Reinforced Concrete (RC) Intermediate Moment Frames (IMF). Although using the IMF is not allowed in high seismic hazard zones according to ASCE 7-10, it is permitted in both Iran's 2800 Seismic Standard and New Zealand's Seismic Code. This study investigates the seismic behavior of a reinforced concrete IMF subjected to earthquake excitations using shaking table tests on a 2D RC structural model which is designed under the regulations of ACI318-19. The scale factor of 1/2.78 is selected for the frame fabrication due to the size limit of the shaking table. The constructed model has three stories with a height as 115 cm for each story, the clear length of beams as 151 cm, and cross-sectional dimensions of columns and beams as 11 $\times$ 11 cm and 12 $\times$ 11 cm, respectively. The whole structure is supported by a foundation that is 173 cm long, 52 cm wide, and 22 cm deep. Columns and beams are reinforced with 8 mm diameter longitudinal ribbed bars and stirrups with 6 mm diameter. The tests are conducted in stages with increasing peak ground acceleration (PGA) till the failure of the frame. Sarpol-E-Zahab earthquake seismic record is adopted for the experiment. The structural responses (e.g., displacements, longitudinal bars' strain, crack propagation, accelerations) are monitored during the test using both conventional sensors and vison-based sensors. As a comparative study, both conventional sensors and computer vision techniques are used to monitor the health state and to analyze the structural dynamics of the scaled RC frame structure.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑