arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2402.18236cs.CV
收藏

Image2Flow:一种用于从3D心脏MRI数据中快速进行患者特异性肺动脉分割和CFD流场计算的混合图像与图卷积神经网络

Image2Flow: A hybrid image and graph convolutional neural network for rapid patient-specific pulmonary artery segmentation and CFD flow field calculation from 3D cardiac MRI data

Institute of Cardiovascular Science, University College London(伦敦大学学院心血管科学研究所)

Tina Yao, Endrit Pajaziti, Michael Quail, Silvia Schievano, Jennifer A Steeden, Vivek Muthurangu

AI总结:

本文提出混合图像与图卷积网络Image2Flow,从3D心脏MRI直接生成患者特异性肺动脉体网格并估计CFD压力与流场,精度优异且推理约205毫秒。

摘要:

计算流体动力学(CFD)可用于评估血流动力学。然而,其常规应用受到劳动密集型人工分割、CFD网格创建以及耗时模拟的限制。本研究旨在训练一个深度学习模型,既能根据3D心脏MRI数据生成患者特异性肺动脉体网格,又能直接估计CFD流场。本研究使用了来自公共和私有数据集的135例3D心脏MRI。MRI中的肺动脉经人工分割并转换为体网格。在真实网格上执行CFD模拟,并将结果插值到逐点对应的网格上,以创建真实数据集。数据集按85/10/15的比例划分为训练集、验证集和测试集。研究训练了混合图像与图卷积神经网络Image2Flow,将肺动脉模板转换为患者特异性解剖结构和CFD数值。Image2Flow在分割方面接受评估,并通过逐节点比较评估CFD预测的准确性。研究还对Image2Flow与使用机器学习分割执行的CFD模拟进行了中心线比较。Image2Flow取得了优异的分割精度,Dice分数中位数为0.9(IQR:0.86–0.92)。压力和速度幅值的逐节点归一化绝对误差中位数分别为11.98%(IQR:9.44–17.90%)和8.06%(IQR:7.54–10.41)。中心线分析显示,Image2Flow与在机器学习生成的体网格上模拟的传统CFD之间没有显著差异。这项概念验证研究表明,同时执行基于患者特异性体网格的分割以及压力和流场估计是可能的。Image2Flow在约205毫秒内完成分割和CFD,比人工方法快约7000倍,使其在临床环境中更具可行性。

英文摘要:

Computational fluid dynamics (CFD) can be used for evaluation of hemodynamics. However, its routine use is limited by labor-intensive manual segmentation, CFD mesh creation, and time-consuming simulation. This study aims to train a deep learning model to both generate patient-specific volume-meshes of the pulmonary artery from 3D cardiac MRI data and directly estimate CFD flow fields. This study used 135 3D cardiac MRIs from both a public and private dataset. The pulmonary arteries in the MRIs were manually segmented and converted into volume-meshes. CFD simulations were performed on ground truth meshes and interpolated onto point-point correspondent meshes to create the ground truth dataset. The dataset was split 85/10/15 for training, validation and testing. Image2Flow, a hybrid image and graph convolutional neural network, was trained to transform a pulmonary artery template to patient-specific anatomy and CFD values. Image2Flow was evaluated in terms of segmentation and accuracy of CFD predicted was assessed using node-wise comparisons. Centerline comparisons of Image2Flow and CFD simulations performed using machine learning segmentation were also performed. Image2Flow achieved excellent segmentation accuracy with a median Dice score of 0.9 (IQR: 0.86-0.92). The median node-wise normalized absolute error for pressure and velocity magnitude was 11.98% (IQR: 9.44-17.90%) and 8.06% (IQR: 7.54-10.41), respectively. Centerline analysis showed no significant difference between the Image2Flow and conventional CFD simulated on machine learning-generated volume-meshes. This proof-of-concept study has shown it is possible to simultaneously perform patient specific volume-mesh based segmentation and pressure and flow field estimation. Image2Flow completes segmentation and CFD in ~205ms, which ~7000 times faster than manual methods, making it more feasible in a clinical environment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑