开发并验证一种人工智能模型以准确预测脊柱骨盆参数

Development and validation of an artificial intelligence model to accurately predict spinopelvic parameters

University of Michigan(密歇根大学);Ohio State University(俄亥俄州立大学);University of Tennessee(田纳西大学)
Edward S. Harake, Joseph R. Linzey, Cheng Jiang, Rushikesh S. Joshi, Mark M. Zaki, Jaes C. Jones, Siri S. Khalsa, John H. Lee, Zachary Wilseck, Jacob R. Joseph,… 展开作者

Edward S. Harake, Joseph R. Linzey, Cheng Jiang, Rushikesh S. Joshi, Mark M. Zaki, Jaes C. Jones, Siri S. Khalsa, John H. Lee, Zachary Wilseck, Jacob R. Joseph, Todd C. Hollon, Paul Park

AI总结:

本研究提出并验证了AI工具SpinePose,基于761张X光片训练,自动预测脊柱骨盆参数,误差小且可靠性高,媲美专家,有助于患者选择和手术规划。

摘要:

目的。已证明实现适当的脊柱骨盆对线可改善临床症状。然而,测量脊柱骨盆影像学参数耗时且观察者间可靠性令人担忧。自动化测量工具承诺提供快速且一致的测量,但现有工具仍受限于某种程度的人工用户输入需求。本研究提出了一种名为SpinePose的新型人工智能(AI)工具,无需人工输入即可高精度自动预测脊柱骨盆参数。方法。SpinePose在761张矢状全脊柱X光片上训练并验证,以预测矢状垂直轴(SVA)、骨盆倾斜(PT)、骨盆入射角(PI)、骶骨倾斜(SS)、腰椎前凸(LL)、T1-骨盆角(T1PA)和L1-骨盆角(L1PA)。一个包含40张X光片的独立测试集由4名评审者标注,其中包括接受过专科培训的脊柱外科医生和一名具有神经放射学亚专科认证的专科培训放射科医生。计算相对于最资深评审者的中位误差以确定模型在测试图像上的准确性。使用组内相关系数(ICC)评估评审者间可靠性。结果。SpinePose表现出以下参数误差中位数(四分位距):SVA:2.2(2.3)毫米,p=0.93;PT:1.3(1.2)°,p=0.48;SS:1.7(2.2)°,p=0.64;PI:2.2(2.1)°,p=0.24;LL:2.6(4.0)°,p=0.89;T1PA:1.1(0.9)°,p=0.42;L1PA:1.4(1.6)°,p=0.49。模型预测在所有参数上也表现出极佳的可靠性(ICC:0.91-1.0)。结论。SpinePose准确预测了脊柱骨盆参数,其可靠性极佳,可与接受专科培训的脊柱外科医生和神经放射科医生相媲美。在脊柱影像中利用预测性AI工具可显著辅助患者选择和手术规划。

英文摘要:

Objective. Achieving appropriate spinopelvic alignment has been shown to be associated with improved clinical symptoms. However, measurement of spinopelvic radiographic parameters is time-intensive and interobserver reliability is a concern. Automated measurement tools have the promise of rapid and consistent measurements, but existing tools are still limited by some degree of manual user-entry requirements. This study presents a novel artificial intelligence (AI) tool called SpinePose that automatically predicts spinopelvic parameters with high accuracy without the need for manual entry. Methods. SpinePose was trained and validated on 761 sagittal whole-spine X-rays to predict sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), lumbar lordosis (LL), T1-pelvic angle (T1PA), and L1-pelvic angle (L1PA). A separate test set of 40 X-rays was labeled by 4 reviewers, including fellowship-trained spine surgeons and a fellowship-trained radiologist with neuroradiology subspecialty certification. Median errors relative to the most senior reviewer were calculated to determine model accuracy on test images. Intraclass correlation coefficients (ICC) were used to assess inter-rater reliability. Results. SpinePose exhibited the following median (interquartile range) parameter errors: SVA: 2.2(2.3)mm, p=0.93; PT: 1.3(1.2)°, p=0.48; SS: 1.7(2.2)°, p=0.64; PI: 2.2(2.1)°, p=0.24; LL: 2.6(4.0)°, p=0.89; T1PA: 1.1(0.9)°, p=0.42; and L1PA: 1.4(1.6)°, p=0.49. Model predictions also exhibited excellent reliability at all parameters (ICC: 0.91-1.0). Conclusions. SpinePose accurately predicted spinopelvic parameters with excellent reliability comparable to fellowship-trained spine surgeons and neuroradiologists. Utilization of predictive AI tools in spinal imaging can substantially aid in patient selection and surgical planning.