多通道Q-Pix原型机的首次运行:测量气体时间投影室中的电子横向扩散

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

Nora Hoch, Olivia Seidel, Varghese A. Chirayath, Alfredo Enriquez, Elena Gramellini, Roxanne Guenette, I-See W. Jaidee, Kevin Keefe, Shahab Kohani, Shion Kubota… 展开作者

Nora Hoch, Olivia Seidel, Varghese A. Chirayath, Alfredo Enriquez, Elena Gramellini, Roxanne Guenette, I-See W. Jaidee, Kevin Keefe, Shahab Kohani, Shion Kubota, Hany Mahdy, Austin McDonald, Yuan Mei, Peng Miao, F. Mitch Newcomer, David Nygren, Ilker Parmaksiz, Michael Rooks, Iakovos Tzoka, Wenzhao Wei, Jonathan Asaadi, James B. R. Battat

AI总结:

本文首次运行16通道Q-Pix原型机,在气体时间投影室中测量P-10气体中电子的横向扩散,实验结果与PyBoltz模拟一致,验证了Q-Pix读出技术重建电离拓扑的能力。

摘要:

我们报告了在实验室规模的时间投影室(TPC)中,利用一种称为Q-Pix的新型像素化信号采集与数字化技术,对P-10气体(90% Ar,10% CH4)中电子横向扩散的测量结果。Q-Pix方法采用一个精密开关积分跨阻放大器,其输出与阈值电压进行比较。当达到阈值时,比较器发出“复位”信号,启动积分电容的放电。相邻两次复位之间的时间差与该时间间隔内像素上的平均电流成反比,而复位次数与收集到的总电荷成正比。我们开发了一个由商用现成组件构成的16通道Q-Pix原型机,并将其耦合到16个同心环形阳极电极上,以测量电子群在穿过TPC均匀电场漂移后到达阳极时的空间范围。电子群是在金光电阴极上使用脉冲紫外光产生的。在200-1500 Torr的工作压力范围内,测得的横向扩散与PyBoltz模拟结果一致。这些结果表明,Q-Pix读出系统能够成功重建TPC中的电离拓扑结构。

英文摘要:

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.