基于IMU的关节旋转中心自适应估计器用于运动分析

Novel IMU-based Adaptive Estimator of the Center of Rotation of Joints for Movement Analysis

Sara García-de-Villa, Ana Jiménez-Martín, J. Jesús García-Domínguez

AI总结:

本文提出ArVEd,一种基于单个IMU和扩展卡尔曼滤波器的实时关节旋转中心估计器,能自适应软组织伪影引起的微小变化,在合成和真实实验中均优于现有方法。

摘要:

关节旋转中心(COR)的位置是人体运动分析多个应用中的关键参数。本研究旨在提出一种利用惯性测量单元(IMU)的新型实时固定关节旋转中心估计器。由于软组织伪影(STA)的存在,关节运动过程中到该中心的距离通常会发生变化,因此我们的方法旨在当COR固定时适应这些微小变化。我们的方案名为ArVEd,据我们所知,这是首个基于单个IMU的IMU-关节中心向量的实时估计器。以往的工作都是离线的,需要完整的测量批次才能求解,且大多数未在真实场景中进行测试。该算法基于扩展卡尔曼滤波器(EKF),在每个时刻提供对STA运动变化自适应的向量,无需预处理阶段来降低噪声水平。ArVEd已通过不同实验进行了测试,包括合成数据和真实数据。合成数据来自一个模拟的球形摆,其COR固定,同时考虑了恒定和可变的IMU-关节向量,以模拟因STA引起的IMU平移运动。结果表明,ArVEd能够适应并每样本获得一个向量,在合成数据上的精度为6.8±3.9,这意味着误差低于模拟IMU-关节向量的3.5%。其准确性也在真实场景中进行了测试,以光学系统的结果作为参考,估计了5名志愿者的髋关节COR。在此情况下,ArVEd的平均误差为真实向量值的9.5%。在所有实验中,ArVEd均优于参考算法已发表的结果。

英文摘要:

The location of the center of rotation (COR) of joints is a key parameter in multiple applications of human motion analysis. The aim of this work was to propose a novel real-time estimator of the center of fixed joints using an inertial measurement unit (IMU). Since the distance to this center commonly varies during the joint motion due to soft tissue artifacts (STA), our approach is aimed at adapting to these small variations when the COR is fixed. Our proposal, called ArVEd, to the best of our knowledge, is the first real-time estimator of the IMU-joint center vector based on one IMU. Previous works are off-line and require a complete measurement batch to be solved and most of them are not tested on the real scenario. The algorithm is based on an Extended Kalman Filter (EKF) that provides an adaptive vector to STA motion variations at each time instant, without requiring a pre-processing stage to reduce the level of noise. ArVEd has been tested through different experiments, including synthetic and real data. The synthetic data are obtained from a simulated spherical pendulum whose COR is fixed, considering both a constant and a variable IMU-joint vector, that simulates translational IMU motions due to STA. The results prove that ArVEd is adapted to obtain a vector per sample with an accuracy of 6.8$\pm$3.9 on the synthetic data, that means an error lower than 3.5% of the simulated IMU-joint vector. Its accuracy is also tested on the real scenario estimating the COR of the hip of 5 volunteers using as reference the results from an optical system. In this case, ArVEd gets an average error of 9.5% of the real vector value. In all the experiments, ArVEd outperforms the published results of the reference algorithms.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑