arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2402.00320eess.IV
收藏

DARCS:用于加速3D全心冠状动脉MR血管造影的内存高效型深度压缩感知重建

DARCS: Memory-Efficient Deep Compressed Sensing Reconstruction for Acceleration of 3D Whole-Heart Coronary MR Angiography

Zhihao Xue, Fan Yang, Juan Gao, Zhuo Chen, Hao Peng, Chao Zou, Hang Jin, Chenxi Hu

AI总结:

针对3D冠状动脉MR血管造影重建中展开式深度网络内存占用高的问题,提出基于预训练伪影估计网络作稀疏变换的DARCS方法,在提升重建质量的同时仅需MoDL 63%的内存,且泛化性良好。

摘要:

三维冠状动脉磁共振血管造影(CMRA)需要能够显著抑制高度欠采样采集产生的伪影的重建算法。虽然基于展开的深度重建方法已在2D图像重建上取得了最优性能,但由于训练展开网络所需的内存量巨大,其在3D重建中的应用受到阻碍。在本研究中,我们通过采用基于预训练伪影估计网络的稀疏化变换,提出了一种内存高效的深度压缩感知方法。其核心思路是:当输入图像无伪影时,训练良好的网络估计出的伪影图像具有稀疏性,而当输入图像受伪影影响时,伪影图像的稀疏度较低。因此,伪影估计网络可用作固有稀疏化变换。我们将所提出的方法命名为基于去混叠正则化的压缩感知(DARCS),并将其与传统压缩感知方法、去混叠生成对抗网络(DAGAN)、基于模型的深度学习(MoDL)以及即插即用方法在3D CMRA加速任务上进行了对比。结果表明,与对比方法相比,所提方法大幅提升了重建质量。此外,该方法在不同欠采样率和噪声水平下均表现出良好的泛化性。所提方法的内存使用量仅为MoDL所需内存的63%。总之,所提方法在降低内存负担的同时,实现了3D CMRA重建质量的提升。

英文摘要:

Three-dimensional coronary magnetic resonance angiography (CMRA) demands reconstruction algorithms that can significantly suppress the artifacts from a heavily undersampled acquisition. While unrolling-based deep reconstruction methods have achieved state-of-the-art performance on 2D image reconstruction, their application to 3D reconstruction is hindered by the large amount of memory needed to train an unrolled network. In this study, we propose a memory-efficient deep compressed sensing method by employing a sparsifying transform based on a pre-trained artifact estimation network. The motivation is that the artifact image estimated by a well-trained network is sparse when the input image is artifact-free, and less sparse when the input image is artifact-affected. Thus, the artifact-estimation network can be used as an inherent sparsifying transform. The proposed method, named De-Aliasing Regularization based Compressed Sensing (DARCS), was compared with a traditional compressed sensing method, de-aliasing generative adversarial network (DAGAN), model-based deep learning (MoDL), and plug-and-play for accelerations of 3D CMRA. The results demonstrate that the proposed method improved the reconstruction quality relative to the compared methods by a large margin. Furthermore, the proposed method well generalized for different undersampling rates and noise levels. The memory usage of the proposed method was only 63% of that needed by MoDL. In conclusion, the proposed method achieves improved reconstruction quality for 3D CMRA with reduced memory burden.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑