arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2401.13321physics.ins-det
收藏

基于多项式拟合的磁通门传感器温度补偿方法

Temperature Compensation Method of Fluxgate Sensor Based on Polynomial Fitting

Ruiping Yang, Huan Liu, Jian Ge, Daisuke Chugo, Haobin Dong

AI总结:

针对磁通门传感器因环境温度变化产生漂移的问题,提出基于多项式拟合的温度补偿方法,经实验验证可将温度漂移从超过500 nT降至约1 nT。

摘要:

磁通门传感器因其高分辨率和低功耗等良好性能,被广泛应用于低频弱矢量磁场测量领域。然而,在长期连续观测过程中,由于环境温度的变化,磁通门传感器会出现漂移误差。本文提出了一种基于多项式拟合的磁通门传感器温度补偿方法。首先,在COMSOL Multiphysics仿真平台上建立了温度与磁通门传感器的物理模型,并分析了温度对磁通门传感器测量性能的影响。其次,根据现有的温度-磁场数据,构建了磁通门传感器的温度补偿模型,并与其他温度补偿方法进行了比较,结果表明所提出的温度补偿方法相对简单,能更好地实现传感器应用场景中的实时补偿。最后,为验证所提方法的有效性,进行了大量实验室实验。温度漂移从补偿前的超过500 nT降低到约1 nT。结果表明,所提方法在变温背景下对磁通门传感器测得的数据具有良好的温度补偿效果。

英文摘要:

Fluxgate sensors are widely used in the field of low frequency and weak vector magnetic field measurement because of their good performance, such as high resolution and low power consumption. However, during the long-term continuous observation, the drift errors of the fluxgate sensor will occur due to the variable ambient temperature. This paper proposes a temperature compensation method for fluxgate sensors based on polynomial fitting. First, a physical model of the temperature & fluxgate sensor was established on the COMSOL Multiphysics simulation platform, and the influence of temperature on the measurement performance of the fluxgate sensor was analyzed. Second, according to the existing temperature-magnetic field data, a temperature compensation model of the fluxgate sensor was constructed. And compared it with other temperature compensation method, the result shows that the proposed temperature compensation method is relatively simple and can better achieve real-time compensation for sensor application scenarios. Finally, to verify the effectiveness of the proposed method, numerous laboratory experiments were implemented. The temperature drift is reduced from more than 500 nT before compensation to about 1 nT. The results show that the proposed method has a good temperature compensation effect on the data measured by the fluxgate sensor within a variable temperature background.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑