arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2401.09283eess.IVcs.CV
收藏

一种基于梯度的锥形束CT头部运动补偿快速准确方法

A gradient-based approach to fast and accurate head motion compensation in cone-beam CT

Siemens Healthineers AG(西门子医疗集团)

Mareike Thies, Fabian Wagner, Noah Maul, Haijun Yu, Manuela Goldmann, Linda-Sophie Schneider, Mingxuan Gu, Siyuan Mei, Lukas Folle, Alexander Preuhs, Michael Manhart, Andreas Maier

AI总结:

本文提出一种基于梯度的CBCT运动估计方法,利用反投影算子的广义导数和体素级质量图回归网络,实现19倍加速并将重投影误差从3mm降至0.61mm,显著提升头部运动补偿的效率和准确性。

摘要:

锥形束计算机断层扫描(CBCT)系统凭借其灵活性,为直接床旁医学成像提供了一条有前景的途径,尤其是在急性卒中评估等关键场景中。然而,将CBCT整合到临床工作流程中面临挑战,主要与扫描持续时间较长导致患者在扫描过程中发生运动,进而使重建体中的图像质量下降有关。本文提出了一种新的CBCT运动估计方法,使用基于梯度的优化算法,该算法利用了针对锥形束CT几何结构的反投影算子的广义导数。在此基础上,构建了一个完全可微的目标函数,用于在重建空间中评价当前运动估计的质量。我们大幅加速了运动估计,与现有方法相比实现了19倍的加速。此外,我们研究了用于质量度量回归的网络架构,并提出预测体素级质量图,倾向于采用自编码器式架构而非收缩式架构。这一修改改善了梯度流动,从而实现更准确的运动估计。所提出的方法通过在头部解剖结构上的真实实验进行了评估。在运动补偿后,重投影误差从初始平均3mm降低到0.61mm,并且与现有方法相比始终表现出更优越的性能。作为所提方法核心的反投影操作的解析雅可比矩阵已公开发布。总之,本文通过提出一种鲁棒的运动估计方法来提高效率和准确性,从而推动CBCT整合到临床工作流程中,解决时间敏感场景中的关键挑战。

英文摘要:

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3mm to 0.61mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑