arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2401.08340physics.med-phphysics.optics
收藏

利用3D穆勒矩阵成像方法洞察血膜多晶微观结构

Insights into Polycrystalline Microstructure of Blood Films with 3D Mueller Matrix Imaging Approach

Volodimyr A. Ushenko, Anton Sdobnov, Liliya Trifonyuk, Alexander V. Dubolazov, Alexander Doronin, Yuriy A. Ushenko, Irina V. Soltys, Mykhailo P. Gorsky, Alexand… 展开作者

Volodimyr A. Ushenko, Anton Sdobnov, Liliya Trifonyuk, Alexander V. Dubolazov, Alexander Doronin, Yuriy A. Ushenko, Irina V. Soltys, Mykhailo P. Gorsky, Alexander G. Ushenko, Vyacheslav K. Gantyuk, Wenjun Yan, Alexander Bykov, Igor Meglinski

AI总结:

本文提出基于数字全息的3D穆勒矩阵成像技术,逐层分析血膜多晶结构中的光学各向异性,发现3阶和4阶统计矩对早期前列腺癌诊断及分期区分准确率超过90%。

摘要:

我们引入一种基于数字全息方法的3D穆勒矩阵(MM)图像重建技术,用于对具有多晶结构的薄膜(如脱水血涂片)进行逐层剖析。所提方法有效提取光学各向异性参数,以进行详细的定量分析。研究揭示了该方法对血液蛋白质四级和三级结构改变所引起的光学各向异性细微变化具有敏感性,这些变化会在疾病极早期导致宏观层面结晶结构的紊乱。在来自健康组织和不同阶段腺癌的前列腺癌组织的部分退偏多晶血膜中,分析了线性和圆双折射及二向色性的空间分布。观察并量化了表征涂片体积不同相位截面中光学各向异性分布的1至4阶统计矩值的变化。对健康患者光学各向异性分布的比较分析表明,线性和圆双折射及二向色性的3阶和4阶统计矩最具诊断前景。我们在早期癌症诊断及其分期区分方面取得了优异准确率(>90%),证明该技术相较于现有筛查方法在快速、准确的确定性癌症诊断方面具有显著潜力。

英文摘要:

We introduce a 3D Mueller Matrix (MM) image reconstruction technique using digital holographic approach for the layer-by-layer profiling thin films with polycrystalline structures, like dehydrated blood smears. The proposed method effectively extracts optical anisotropy parameters for a detailed quantitative analysis. The investigation revealed the method sensitivity to subtle changes in optical anisotropy properties resulting from alterations in the quaternary and tertiary structures of blood proteins, leading to disturbances in crystallization structures at the macro level at the very early stage of a disease. Spatial distributions of linear and circular birefringence and dichroism are analyzed in partially depolarizing polycrystalline blood films obtained from healthy tissues and cancerous prostate tissues at various stages of adenocarcinoma. Changes in the values of the 1st to 4th order statistical moments, characterizing the distributions of optical anisotropy in different phase sections of the smear volumes, are observed and quantified. Comparative analysis of optical anisotropy distributions from healthy patients highlighted the 3rd and 4th order statistical moments for linear and circular birefringence and dichroism as the most promising for diagnostic purposes. We achieved an excellent accuracy (>90%) for early cancer diagnosis and differentiation of its stages, demonstrating the techniques significant potential for rapid and accurate definitive cancer diagnosis compared to existing screening approaches.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑