arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2312.16935physics.app-ph
收藏

集成光学电场传感器:湿度稳定性机制与封装方案

Integrated Optical Electric Field Sensors: Humidity Stability Mechanisms and Packaging Scheme

Xinyu Ma, Chijie Zhuang, She Wang, Rong Zeng

AI总结:

本文针对集成光学电场传感器在户外高湿环境下的精度退化问题,提出采用PEEK外壳与室温硫化氟化硅橡胶涂层的封装方案,将RH 90%下的相位偏移从90°降至1°,幅度偏差从20%降至近零,显著提升湿度稳定性。

摘要:

集成光学电场传感器(IOES)在电场测量中发挥着至关重要的作用。本文介绍了IOES的原理,并定量评估了湿度对测量精度的影响。制备并测试了具有不同疏水涂层和吸湿性外壳的传感器,测试范围为相对湿度(RH)25%至95%。结果表明,湿度稳定性主要受水蒸气通过传感器外壳吸收的影响,这增加了其电导率,进而导致传感器输出的幅度偏差和相位偏移。为解决此问题,提出了一种优化的湿度稳定封装方案,该方案采用PEEK外壳并涂覆室温硫化氟化硅橡胶涂层。与未涂覆的陶瓷外壳相比,在RH为90%的条件下,IOES的相位偏移从90°降至1°。在30°C、RH为90%的条件下进行的20小时湿度实验中,电场测量的幅度偏差从20%降至接近零。所提出的封装方案可用于提高部署在户外环境(尤其是船舶和沿海地区)中传感器的湿度稳定性。

英文摘要:

Integrated optical electric field sensors (IOES) play a crucial role in electric field measurement. This paper introduces the principles of the IOES and quantitatively evaluates the impact of humidity on measurement accuracy. Sensors with different levels of hydrophobicity coatings and hygroscopicity shells are fabricated and tested across the relative humidity (RH) range of 25% to 95%. Results reveal that humidity stability is primarily influenced by water vapor absorption through the sensor shell, which increases its conductivity. This further results in amplitude deviation and phase shift of the sensor output. To address this, an optimal humidity-stable packaging scheme is proposed, which involves using PEEK shell with room temperature vulcanized fluorinated silicone rubber coating. Compared with uncoated ceramic shell, the phase shift of the IOES reduces from 90$^\circ$ to 1$^\circ$ under a RH of 90%. The amplitude deviation of electric field measurement decreases from 20% to nearly zero after a 20-hour humidity experiment conducted under RH of 90% at 30 $^\circ$C. The proposed packaging scheme could be used to improve the humidity stability of the sensors deployed in outdoor environments, especially on ships and coastal areas.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑