AI CADe息肉检测器在推广至新国家时的惊人有效性

The unreasonable effectiveness of AI CADe polyp detectors to generalize to new countries

Verily Life Sciences(Verily生命科学公司);Google Japan(谷歌日本);Kyushu University(九州大学);Sapporo Medical University(札幌医科大学)
Joel Shor, Hiro-o Yamano, Daisuke Tsurumaru, Yotami Intrator, Hiroki Kayama, Joe Ledsam, Atsushi Hamabe, Koji Ando, Mitsuhiko Ota, Haruei Ogino, Hiroshi Nakase,… 展开作者

Joel Shor, Hiro-o Yamano, Daisuke Tsurumaru, Yotami Intrator, Hiroki Kayama, Joe Ledsam, Atsushi Hamabe, Koji Ando, Mitsuhiko Ota, Haruei Ogino, Hiroshi Nakase, Kaho Kobayashi, Eiji Oki, Roman Goldenberg, Ehud Rivlin, Ichiro Takemasa

AI总结:

本研究提出无标注的结肠镜差异度量MACE,验证了以色列训练的AI CADe息肉检测器在日本数据上性能非劣,证明医疗AI跨国家泛化的有效性及MACE的评估价值。

摘要:

**背景与目的**:人工智能(AI)计算机辅助检测(CADe,Computer-Aided Detection)被广泛用于息肉检测,但临床场景中的数据可能与模型训练时的数据存在差异。很少有研究评估CADe检测器在训练阶段未接触过的国家的结肠镜检查数据上的表现,且尚无研究能够在无需收集成本高昂、耗时费力的标注的情况下完成性能评估。\n**方法**:我们基于以色列的结肠镜视频(5004个视频,时长1106小时)训练了一个CADe息肉检测器,并在日本的视频(354个视频,时长128小时)上进行评估,评估指标为真阳性率(TPR,True Positive Rate)与每分钟误报数(FAPM,false alarms per minute)的对应关系。我们提出了一种名为“MAsked mediCal Embedding Distance(掩码医学嵌入距离,简称MACE)”的结肠镜差异度量方法,用于在无标注的情况下量化结肠镜检查数据之间的差异。我们在全部日本视频以及MACE值最高的日本视频子集上评估了CADe的性能。\n**结果**:MACE正确量化出,与日本白光图像相比,窄带成像(NBI,narrow-band imaging)和色素内镜(CE,chromoendoscopy)帧与以色列数据的相似度更低(自助法z检验,两者|z| > 690,p < 10^-8)。尽管数据存在差异,在未进行额外训练的情况下,CADe在日本结肠镜数据上的表现不劣于以色列数据(0.5 FAPM下的TPR:以色列0.957,日本0.972;1.0 FAPM下的TPR:以色列0.972,日本0.989;优效性检验t > 45.2,p < 10^-8)。尽管未在NBI或CE数据上训练,该检测器在这些子集上的TPR不劣于日本整体数据(非劣效性检验t > 47.3,p < 10^-8,两者δ均为1.5%)。\n**结论**:在非医疗场景中会导致CADe检测器性能下降的数据差异,并未降低我们的AI CADe息肉检测器应用于新国家数据时的性能。MACE可通过识别最“不同”的评估数据,助力医疗AI模型实现国际化应用。

英文摘要:

$\textbf{Background and aims}$: Artificial Intelligence (AI) Computer-Aided Detection (CADe) is commonly used for polyp detection, but data seen in clinical settings can differ from model training. Few studies evaluate how well CADe detectors perform on colonoscopies from countries not seen during training, and none are able to evaluate performance without collecting expensive and time-intensive labels. $\textbf{Methods}$: We trained a CADe polyp detector on Israeli colonoscopy videos (5004 videos, 1106 hours) and evaluated on Japanese videos (354 videos, 128 hours) by measuring the True Positive Rate (TPR) versus false alarms per minute (FAPM). We introduce a colonoscopy dissimilarity measure called "MAsked mediCal Embedding Distance" (MACE) to quantify differences between colonoscopies, without labels. We evaluated CADe on all Japan videos and on those with the highest MACE. $\textbf{Results}$: MACE correctly quantifies that narrow-band imaging (NBI) and chromoendoscopy (CE) frames are less similar to Israel data than Japan whitelight (bootstrapped z-test, |z| > 690, p < $10^{-8}$ for both). Despite differences in the data, CADe performance on Japan colonoscopies was non-inferior to Israel ones without additional training (TPR at 0.5 FAPM: 0.957 and 0.972 for Israel and Japan; TPR at 1.0 FAPM: 0.972 and 0.989 for Israel and Japan; superiority test t > 45.2, p < $10^{-8}$). Despite not being trained on NBI or CE, TPR on those subsets were non-inferior to Japan overall (non-inferiority test t > 47.3, p < $10^{-8}$, $δ$ = 1.5% for both). $\textbf{Conclusion}$: Differences that prevent CADe detectors from performing well in non-medical settings do not degrade the performance of our AI CADe polyp detector when applied to data from a new country. MACE can help medical AI models internationalize by identifying the most "dissimilar" data on which to evaluate models.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑