Synthetic data (SIM) drawn from simulators have emerged as a popular alternative for training models where acquiring annotated real-world images is difficult. However, transferring models trained on synthetic images to real-world applications can be challenging due to appearance disparities. A commonly employed solution to counter this SIM2REAL gap is unsupervised domain adaptation, where models are trained using labeled SIM data and unlabeled REAL data. Mispredictions made by such SIM2REAL adapted models are often associated with miscalibration - stemming from overconfident predictions on real data. In this paper, we introduce AUGCAL, a simple training-time patch for unsupervised adaptation that improves SIM2REAL adapted models by - (1) reducing overall miscalibration, (2) reducing overconfidence in incorrect predictions and (3) improving confidence score reliability by better guiding misclassification detection - all while retaining or improving SIM2REAL performance. Given a base SIM2REAL adaptation algorithm, at training time, AUGCAL involves replacing vanilla SIM images with strongly augmented views (AUG intervention) and additionally optimizing for a training time calibration loss on augmented SIM predictions (CAL intervention). We motivate AUGCAL using a brief analytical justification of how to reduce miscalibration on unlabeled REAL data. Through our experiments, we empirically show the efficacy of AUGCAL across multiple adaptation methods, backbones, tasks and shifts.
Technical University of Berlin(柏林工业大学);Microsoft Cloud and AI Security(微软云与人工智能安全部门)
Augmented Reality and mobile robots are gaining much attention within industries due to the high potential to make processes cost and time efficient. To facilitate augmented reality, a calibration between the Augmented Reality device and the environment is necessary. This is a challenge when dealing with mobile robots due to the mobility of all entities making the environment dynamic. On this account, we propose a novel approach to calibrate the Augmented Reality device using 3D depth sensor data. We use the depth camera of a cutting edge Augmented Reality Device - the Microsoft Hololens for d…
Improving Mixup Calibration with Wasserstein Distributionally Robust Optimization
Department of Mathematics & Statistics(数学与统计学系);Boston University(波士顿大学);Department of Electrical and Computer Engineering, Division of Systems Engineering(电气与计算机工程系,系统工程 division);Department of Biomedical Engineering(生物医学工程系);Faculty of Computing & Data Sciences(计算与数据科学学院)
In percutaneous orthopedic interventions the surgeon attempts to reduce and fixate fractures in bony structures. The complexity of these interventions arises when the surgeon performs the challenging task of navigating surgical tools percutaneously only under the guidance of 2D interventional X-ray imaging. Moreover, the intra-operatively acquired data is only visualized indirectly on external displays. In this work, we propose a flexible Augmented Reality (AR) paradigm using optical see-through head mounted displays. The key technical contribution of this work includes the marker-less and dyn…
Most recent test-time adaptation methods focus on only classification tasks, use specialized network architectures, destroy model calibration or rely on lightweight information from the source domain. To tackle these issues, this paper proposes a novel Test-time Self-Learning method with automatic Adversarial augmentation dubbed TeSLA for adapting a pre-trained source model to the unlabeled streaming test data. In contrast to conventional self-learning methods based on cross-entropy, we introduce a new test-time loss function through an implicitly tight connection with the mutual information a…
EnCoV-ISIT UMR 6284 CNRS/Université d’Auvergne(法国国家科学研究中心/奥弗涅大学 EnCoV-ISIT 联合研究单位(UMR 6284))
The aim of this work is to implement a simple freehand ultrasound (US) probe calibration technique. This will enable us to visualize US image data during surgical procedures using augmented reality. The performance of the system was evaluated with different experiments using two different pose estimation techniques. A near-millimeter accuracy can be achieved with the proposed approach. The developed system is cost-effective, simple and rapid with low calibration error
For many computer vision applications, the availability of camera calibration data is crucial as overall quality heavily depends on it. While calibration data is available on some devices through Augmented Reality (AR) frameworks like ARCore and ARKit, for most cameras this information is not available. Therefore, we propose a web based calibration service that not only aggregates calibration data, but also allows calibrating new cameras on-the-fly. We build upon a novel camera calibration framework that enables even novice users to perform a precise camera calibration in about 2 minutes. This…
Tracking object poses in 3D is a crucial building block for Augmented Reality applications. We propose an instant motion tracking system that tracks an object's pose in space (represented by its 3D bounding box) in real-time on mobile devices. Our system does not require any prior sensory calibration or initialization to function. We employ a deep neural network to detect objects and estimate their initial 3D pose. Then the estimated pose is tracked using a robust planar tracker. Our tracker is capable of performing relative-scale 9-DoF tracking in real-time on mobile devices. By combining use…
Augmented Reality (AR) brings immersive experiences to users. With recent advances in computer vision and mobile computing, AR has scaled across platforms, and has increased adoption in major products. One of the key challenges in enabling AR features is proper anchoring of the virtual content to the real world, a process referred to as tracking. In this paper, we present a system for motion tracking, which is capable of robustly tracking planar targets and performing relative-scale 6DoF tracking without calibration. Our system runs in real-time on mobile phones and has been deployed in multip…
Université Laval(拉瓦尔大学);Thales Digital Solutions(泰雷兹数字解决方案);Inria(法国国家信息与自动化研究所)
Augmented reality devices require multiple sensors to perform various tasks such as localization and tracking. Currently, popular cameras are mostly frame-based (e.g. RGB and Depth) which impose a high data bandwidth and power usage. With the necessity for low power and more responsive augmented reality systems, using solely frame-based sensors imposes limits to the various algorithms that needs high frequency data from the environement. As such, event-based sensors have become increasingly popular due to their low power, bandwidth and latency, as well as their very high frequency data acquisi…
SurgNavAR: An Augmented Reality Surgical Navigation Framework for Optical See-Through Head Mounted Displays
Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC(鹿特丹伊拉斯姆斯大学医学中心放射与核医学系鹿特丹生物医学成像组);Department of Oral and Maxillofacial Surgery, Erasmus MC(鹿特丹伊拉斯姆斯大学医学中心口腔颌面外科);University of Groningen(格罗宁根大学);Department of High Performance Compute & Visualization, SURF bv(SURF bv高性能计算与可视化部);Department of Neurosurgery, Erasmus MC(鹿特丹伊拉斯姆斯大学医学中心神经外科);Trauma Research Unit, Department of Surgery, Erasmus MC(鹿特丹伊拉斯姆斯大学医学中心外科创伤研究单元)
Institute of Research and Technology b<>com(b<>com技术研究院)
Purpose. Ability to locate and track ultrasound images in the 3D operating space is of great benefit for multiple clinical applications. This is often accomplished by tracking the probe using a precise but expensive optical or electromagnetic tracking system. Our goal is to develop a simple and low cost augmented reality echography framework using a standard RGB-D Camera. Methods. A prototype system consisting of an Occipital Structure Core RGB-D camera, a specifically-designed 3D marker, and a fast point cloud registration algorithm FaVoR was developed and evaluated on an Ultrasonix ultrasoun…
Augmented Reality has been subject to various integration efforts within industries due to its ability to enhance human machine interaction and understanding. Neural networks have achieved remarkable results in areas of computer vision, which bear great potential to assist and facilitate an enhanced Augmented Reality experience. However, most neural networks are computationally intensive and demand huge processing power thus, are not suitable for deployment on Augmented Reality devices. In this work we propose a method to deploy state of the art neural networks for real time 3D object localiza…
University of Würzburg(维尔茨堡大学);Fraunhofer Institute for Integrated Circuits IIS(弗劳恩霍夫集成电路研究所IIS);University Hospital Würzburg(维尔茨堡大学医院);Research Centre for Natural Sciences(自然科学研究中心)
Purpose: To evaluate an iterative learning approach for enhanced performance of Robust Artificial-neural-networks for K-space Interpolation (RAKI), when only a limited amount of training data (auto-calibration signals, ACS) are available for accelerated standard 2D imaging. Methods: In a first step, the RAKI model was optimized for the case of strongly limited training data amount. In the iterative learning approach (termed iterative RAKI), the optimized RAKI model is initially trained using original and augmented ACS obtained from a linear parallel imaging reconstruction. Subsequently, the RA…
The University of Tokyo(东京大学);Tokyo Institute of Technology(东京工业大学)
We propose a spatial calibration method for wide Field-of-View (FoV) Near-Eye Displays (NEDs) with complex image distortions. Image distortions in NEDs can destroy the reality of the virtual object and cause sickness. To achieve distortion-free images in NEDs, it is necessary to establish a pixel-by-pixel correspondence between the viewpoint and the displayed image. Designing compact and wide-FoV NEDs requires complex optical designs. In such designs, the displayed images are subject to gaze-contingent, non-linear geometric distortions, which explicit geometric models can be difficult to repre…
CalexNet: Soft Cascade-Aligned Training and Calibration for Lightweight Early-Exit Branches
Intelligent Systems, Afeka Academic College of Engineering(阿法卡学术工程学院智能系统);School of Computer Science, Faculty of Sciences, Holon Institute of Technology(霍洛恩理工学院计算机科学学院)