具有锥度、生理边界条件和可变壁特性的柔性管中脉搏波传播的解析解及其在患者特异性动脉树中的应用
Analytic solution for pulse wave propagation in flexible tubes with application to patient-specific arterial tree
AI总结:
本研究提出考虑锥度、生理边界与可变壁特性的动脉脉搏波传播解析解,经三维流固耦合模拟验证,揭示壁特性与RCR边界对输入阻抗的影响规律,并成功应用于患者特异性动脉树建模,误差较小。
摘要:
本文提出了一种考虑锥度、生理边界条件和可变壁特性(壁弹性与厚度)的柔性动脉模型中脉搏波传播的解析解。壁特性的变化遵循与$r^α$成正比的分布,其中$r$代表管腔半径,$α$为材料系数。通过求解由质量守恒和动量守恒推导得到的双曲型方程组,获得了截面平均速度和压力,二者分别用阶数为$(4-α)/(3-α)$和$1/(3-α)$的贝塞尔函数表示。通过与三维流固耦合模拟的数值结果对比,该解析解得到了成功验证。随后,该解被用于研究动脉模型中的脉搏波传播,结果表明壁特性以及RCR模型等生理出口边界条件在表征输入阻抗和反射系数方面起着关键作用。在低频范围内,输入阻抗对壁特性不敏感,主要由RCR参数决定;在高频范围内,输入阻抗围绕局部特性阻抗振荡,且振荡幅度随$α$呈非单调变化。本文还给出了低频和高频极限下输入阻抗的表达式。该解析解也被成功应用于模拟患者特异性动脉树内的血流,与三维数值模拟结果相比,压力和流量的最大相对误差分别不超过$1.6\%$和$9.0\%$。
英文摘要:
In this paper, we present an analytic solution for pulse wave propagation in a flexible arterial model with tapering, physiological boundary conditions and variable wall properties (wall elasticity and thickness). The change of wall properties follows a profile that is proportional to $r^α$, where $r$ represents the lumen radius and $α$ is a material coefficient. The cross-sectionally averaged velocity and pressure are obtained by solving a hyperbolic system derived from the mass and momentum conservations, and they are expressed in Bessel functions of order $(4-α)/(3-α)$ and $1/(3-α)$, respectively. The solution is successfully validated by comparing it with numerical results from 3D fluid-structure interaction simulations. Subsequently, the solution is employed to study pulse wave propagation in an arterial model, revealing that the wall properties and the physiological outlet boundary conditions, such as the RCR model, play a crucial role in characterizing the input impedance and reflection coefficient. At low-frequency range, the input impedance is found to be insensitive to the wall properties and is primarily determined by the RCR parameters. At high-frequency range, the input impedance oscillates around the local characteristic impedance, and the oscillation amplitude varies non-monotonically with $α$. Expressions for the input impedance at both low-frequency and high-frequency limits are presented. This analytic solution is also successfully applied to model flow inside a patient-specific arterial tree, with the maximum relative errors in pressure and flow rate never exceeding $1.6\%$ and $9.0\%$ when compared to results from 3D numerical simulation.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。