arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2311.12653physics.acc-phhep-exnucl-ex
收藏

Apollon拍瓦激光产生中子场的综合表征

A Comprehensive Characterization of the Neutron Fields Produced by the Apollon Petawatt Laser

Ronan Lelièvre, Weipeng Yao, Tessa Waltenspiel, Itamar Cohen, Arie Beck, Erez Cohen, David Michaeli, Ishay Pomerantz, Donald Cort Gautier, François Trompier, Qu… 展开作者

Ronan Lelièvre, Weipeng Yao, Tessa Waltenspiel, Itamar Cohen, Arie Beck, Erez Cohen, David Michaeli, Ishay Pomerantz, Donald Cort Gautier, François Trompier, Quentin Ducasse, Pavlos Koseoglou, Pär-Anders Söderström, François Mathieu, Amokrane Allaoua, Julien Fuchs

AI总结:

该研究在Apollon装置上表征F2束驱动的pitcher-catcher中子源,结合多种诊断与模拟给出约4×10^7中子/发,并发现DPM可在保持中子产额的同时降低X射线。

摘要:

二十年来,激光驱动的中子发射一直受到研究,因为它们构成了传统中子源的一种互补来源,并具有更多不同的特性(即更短的束团持续时间和每束团更高的中子数)。我们在此报告了在Apollon激光装置上利用次级激光束(F2)产生的中子场的全面、细致表征。实验使用双等离子体反射镜(DPM)来改善激光的时间对比度;该激光输出持续时间为24 fs的脉冲,靶上平均能量约为10 J,最高频率为每分钟1发。激光与超薄靶(几十或几百nm)在超高条件下相互作用,产生了增强的质子束(最高达35 MeV),随后利用pitcher-catcher技术使这些质子束产生中子。文中给出了这些中子发射的表征,结果来自模拟以及使用多种诊断手段(活化样品、气泡探测器和飞行时间探测器)的测量,得到约4×10^7中子/发的中子产额。在使用和不使用DPM的打靶中观察到相似的中子发射,而使用DPM时产生的X射线更少,这使得该工具有望用于调节中子/X射线比例,以服务于中子/X射线联合射线照相之类的应用。

英文摘要:

Since two decades, laser-driven neutron emissions are studied as they represent a complementary source to conventional neutron sources, with further more different characteristics (i.e. shorter bunch duration and higher number of neutrons per bunch). We report here a global, thorough characterization of the neutron fields produced at the Apollon laser facility using the secondary laser beam (F2). A Double Plasma Mirror (DPM) was used to improve the temporal contrast of the laser which delivers pulses of 24 fs duration, a mean on-target energy of ~10 J and up to 1 shot/min. The interaction of the laser with thin targets (few tens or hundreds of nm) in ultra-high conditions produced enhanced proton beams (up to 35 MeV), which were then used to generate neutrons via the pitcher-catcher technique. The characterization of these neutron emissions is presented, with results obtained from both simulations and measurements using several diagnostics (activation samples, bubble detectors and Time-of-Flight detectors), leading to a neutron yield of ~$4.10^{7}$ neutrons/shot. Similar neutron emissions were observed during shots with and without DPM, while fewer X-rays are produced when the DPM is used, making this tool interesting to adjust the neutrons/X-rays ratio for some applications like combined neutron/X-ray radiography.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑