关于在LPA LPI上搜索磁星SGR1935+2154脉冲辐射的研究
About the search for pulsed radiation from the magnetar SGR1935+2154 at the LPA LPI
AI总结:
本研究在LPA射电望远镜111 MHz观测中核查磁星SGR1935+2154的脉冲辐射,使用不同分辨率数据搜索,未发现S/N>4的脉冲信号。
摘要:
J1935+2154已知为软伽马射线源。2020年5月,FAST望远镜在1.25 GHz频率上探测到来自该磁星的超级耀发。该磁星被纳入LPA射电望远镜在111 MHz频率进行的巡天观测。我们对先前发表(Fedorova等人,2021年)的来自磁星SGR1935+2154的脉冲进行了核查。LPA接收的数据以两种模式并行记录,分别具有低和高频率-时间分辨率:6个通道,通道宽度为415 kHz,时间分辨率为Δt = 100 ms;32个通道,通道宽度为78 kHz,时间分辨率为Δt = 12.5 ms。原始搜索使用低时间-频率分辨率的数据进行。在米波段搜索色散信号比在分米波段更困难,原因是散射与频率的四次方成正比,而脉冲在频率通道中的色散展宽与频率的二次方成正比。为了收集展宽的脉冲信号并获得最佳的S/N值,搜索采用了基于多通道数据与散射脉冲模板卷积的算法。模板形状对应于色散量(DM)为375 pc/cm3的散射脉冲形状。为进行重复验证,使用了与探测到磁星脉冲时相同的数据。此外,还使用具有更高频率-时间分辨率的数据对已发表的脉冲进行了额外检查。由于32通道数据中频率通道的色散展宽比6通道数据小5倍,预期脉冲的S/N值可提高约2倍。在32通道和6通道数据中均未探测到S/N>4且脉冲峰值随DM变化的来自SGR1935+2154的脉冲辐射。
英文摘要:
J1935+2154 is known as a source of soft gamma radiation. Hyperflares from magnetar were detected at a frequency of 1.25 GHz on the FAST telescope in May 2020. The magnetar enters the survey conducted on LPA radio telescope at 111 MHz. A check of the previously published (Fedorova et al. 2021) pulse from the magnetar SGR1935+2154 was carried out. The data received on the LPA is recorded in parallel in two modes having low and high frequency-time resolution: 6 channels with a channel width of 415 kHz and a time resolution of Δt = 100 ms; 32 channels with a channel width of 78 kHz and a time resolution of Δt = 12.5 ms. The original search was carried out using data with low time-frequency resolution. The search for dispersed signals in the meter wavelength range is difficult, compared with the search in the decimeter range, due to scattering proportional to the fourth power of frequency and dispersion smearing of the pulse in frequency channels proportional to the second power of frequency. In order to collect a broadened pulse signal and obtain the best value of S/N, the search was carried out using an algorithm based on the convolution of multichannel data with a scattered pulse pattern. The shape of the template corresponds to the shape of a scattered pulse with a dispersion measure (DM) of 375 pc/cm3. For repeated verification, the same data was used in which the pulse from the magnetar was detected. An additional check of the published pulse was also carried out using data with a higher frequency-time resolution. Since the dispersion smearing in the frequency channel in the 32-channel data is 5 times less than in the 6-channel data, an increase approximately 2 times in the S/N pulse could be expected. Pulse radiation with S/N>4 having a pulse peak shift depending on DM from SGR1935+2154 was not detected in either 32-channel or 6-channel data.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。