AI总结:

本研究提出基于MR信号方程的T2w FLAIR MRI采集偏移模拟框架,用于压力测试AI分割网络,发现F1值与TE、TI呈二次关系且TE影响更大,可定量评估参数对分割性能的影响。

摘要:

目的:提供一种用于常规神经影像测试数据的模拟框架,可针对T2加权(T2w)液体衰减反转恢复(FLAIR)磁共振成像(MRI)协议在临床实践中常见的采集偏移,对深度分割网络开展“压力测试”。\n方法:该方法基于MR信号方程模拟MR图像的“采集偏移衍生图像”。实验内容包括通过真实MR扫描验证模拟图像,以及对当前最优的MS(多发性硬化)病灶分割网络开展示例压力测试,以探索一个通用模型函数,用于描述F1值与影响对比度的序列参数回波时间(TE)和反转时间(TI)之间的依赖关系。\n结果:在极端参数设置下,真实图像与模拟图像在灰质和白质中的差异最高可达19%。对于受测试的分割网络,F1值对TE和TI的依赖关系可通过二次模型函数很好地描述(R²>0.9)。模型函数的系数表明,TE的变化对模型性能的影响大于TI。\n结论:我们证明这些偏差的数值范围与文献中描述的由弛豫时间的误差或个体差异可能导致的偏差范围一致。F1模型函数的系数可用于定量比较TE和TI的影响。该方法的局限性主要来自基线信号低的组织(如脑脊液CSF),以及当协议包含因DICOM头文件信息缺失而无法建模的对比度影响措施时。

英文摘要:

Purpose: To provide a simulation framework for routine neuroimaging test data, which allows for "stress testing" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid attenuated inversion recovery (FLAIR) Magnetic Resonance Imaging (MRI) protocols. Approach: The approach simulates "acquisition shift derivatives" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art MS lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI). Results: The differences between real and simulated images range up to 19 % in gray and white matter for extreme parameter settings. For the segmentation networks under test the F1 score dependency on TE and TI can be well described by quadratic model functions (R^2 > 0.9). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI. Conclusions: We show that these deviations are in the range of values as may be caused by erroneous or individual differences of relaxation times as described by literature. The coefficients of the F1 model function allow for quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with the low baseline signal (like CSF) and when the protocol contains contrast-affecting measures that cannot be modelled due to missing information in the DICOM header.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑