arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2310.19203physics.med-phphysics.ins-det
收藏

CANDU乏燃料蒙特卡罗屏蔽计算中的放射生物学影响评估

Radiobiological Impact Evaluation Within Monte-Carlo Shielding Calculations of CANDU Spent Fuel

M. Sallah, C. A. Margeanu, N. Elbassiony, M. Mitwalli, A. Elgarayhi

AI总结:

本文通过蒙特卡罗屏蔽计算评估CANDU乏燃料的放射生物学影响,比较天然铀和低浓缩铀燃料在运输容器屏蔽前后的器官剂量与有效剂量,验证屏蔽有效性并确认剂量处于可接受水平。

摘要:

利用蒙特卡罗屏蔽估算方法评估了CANDU乏燃料对人体健康的放射生物学效应。乏燃料的检查在其从反应堆卸出后进行。考虑了一个特定的冷却时间间隔,重点关注表征乏燃料的辐射剂量率。在一个包含37个燃料元件的CANDU标准燃料棒束中研究了两种燃料:天然铀(NU)燃料和低浓缩铀(SEU)燃料。使用ORIGEN-S算法模拟了燃料燃耗,并获取了描述乏燃料的光子源。采用一个通用的B型不锈钢运输容器进行乏燃料转移,并使用蒙特卡罗MORSE-SGC算法计算了容器壁处以及距运输容器最远8米处空气中的辐射剂量。为确保核安全和辐射防护,乏燃料必须在临时湿式冷却贮存中保存六个月。预计的剂量率较低,从而允许对乏燃料运输容器进行安全操作。在无屏蔽和有屏蔽两种情况下,估算了两种所研究的乏燃料对人体器官产生的相应剂量。由于器官/组织具有不同的敏感性和反应,通过应用组织权重因子评估了人体的有效剂量;这些权重因子并不相等,使用了ICRP规定的功能系数。本研究的当量剂量计算建模结果强调了所采用屏蔽的完全有效性,并达到了可接受的剂量水平。

英文摘要:

The radiobiological effect on the human health of CANDU spent fuel is assessed using Monte Carlo shielding estimates. The examination of spent fuel occurs after it has been discharged from the reactor. A specific cooling interval is considered, with the radiation dose rates that characterize the used fuel being of interest. Two kinds of fuel were studied in a CANDU standard fuel bundle with 37 fuel components: natural uranium (NU) fuel and slightly enriched uranium (SEU) fuel. The fuel burnup was simulated using the ORIGEN-S algorithm, and the photon sources describing the wasted fuel were retrieved. A generic stainless steel shipping cask type B was used for spent fuel transfer, and radiation doses at the cask wall and in the air up to 8 m away from the shipping cask were computed using the Monte Carlo MORSE-SGC algorithm. To ensure nuclear safety and radiation protection, spent fuel must be maintained in temporary wet cooling storage for six months. The projected dosage rates were modest, allowing for the safe handling of the used fuel shipping cask. The corresponding dosages on human body organs for the two considered spent fuels were estimated without and with shielding. Due to the varied sensitivity and reaction of organs/tissue, the effective dosage was evaluated for the human body by applying a tissue-weighting factor; these weighting factors are not equal, and functional coefficients specified by ICRP are used. The equivalent doses calculation modeling findings for the present study underlined the complete effectiveness of the applied shielding and attained the acceptable dose level.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑