用于极化中子反射测量研究软物质的带功能性SiO2涂层的磁对比层
Magnetic contrast layers with functional SiO2 coatings for soft matter studies with polarised neutron reflectometry
AI总结:
本文提出在硅基底上制备SiO2涂覆的Fe磁对比层,用于极化中子反射测量,以替代同位素对比匹配方法研究软物质界面结构,并验证了其对脂质双层表征的适用性。
摘要:
本研究介绍了一种带有可切换磁对比层(MCL)的硅基底,用于在固/液界面进行极化中子反射测量(PNR)实验,以研究软物质表面层。中子反射测量(NR)数据的优势在于,可以通过在同一试样上使用不同的同位素对比来增强结构和成分信息。这种方法通常被称为对比匹配,可以通过使用具有不同同位素对比的溶剂(例如不同的H2O/D2O比例)和/或对分子进行选择性氘代来实现。然而,某些软物质体系可能会受到这种方法的扰动,或者这种方法可能不可行,尤其是对于生物样品。在这种情况下,带有MCL的固体基底是一种有吸引力的替代方案,因为可以利用与基底之间的磁对比来部分恢复关于样品结构的信息。更具体地说,在本研究中,通过离子束溅射沉积在不同尺寸的硅基底上制备了涂覆有SiO2的软磁Fe层。使用XRR、AFM、VSM和PNR对该结构进行了评估。收集到的数据表明,无论基底尺寸和SiO2覆盖层厚度如何,MCL参数都具有高质量和可重复性。与先前提出的使用Au覆盖层的其他类型MCL基底相比,SiO2覆盖层能够再现用于NR实验的标准硅基底的典型表面,并且与多种软物质样品兼容。我们通过在单一溶剂对比下使用即用型50*50*10 mm3基底进行PNR实验来表征脂质双层,展示了这一应用。总之,本文强调了带有MCL的PNR在研究软物质样品方面的潜力。
英文摘要:
This study introduces silicon substrates with a switchable magnetic contrast layer (MCL) for polarised neutron reflectometry experiments (PNR) at solid/liquid interface to study soft matter surface layers. The advantage with neutron reflectometry (NR) data is that structural and compositional information can be enhanced by using different isotopic contrast on the same sample. This approach is normally referred to as contrast matching, which can be achieved by using solvents with different isotopic contrast, e. g. different H2O/D2O ratio, and/or by selective deuteration of the molecules. However, some soft matter system might be perturbed by this approach, or it might not be possible, particularly for biological samples. In this scenario, solid substrates with a MCL are an appealing alternative, as the magnetic contrast with the substrate can be used to partially recover the information on the sample structure. More specifically, in this study, a magnetically soft Fe layer coated with SiO2 was produced by ion-beam sputter deposition on silicon substrates of different sizes. The structure was evaluated using XRR, AFM, VSM, and PNR. The collected data showed high quality and repeatability of the MCL parameters, regardless of the substrate size and thickness of the capping SiO2 layers. As compared to other kinds of substrates with MCL layer previously proposed, which used Au capping layer, the SiO2 capping layer allows to reproduce the typical surface of standard silicon substrate used for NR experiment and compatible with a large variety of soft matter samples. We demonstrated such application, by using ready-to-measure 50*50*10 mm3 substrates in PNR experiments for the characterisation of a lipid bilayer in a single solvent contrast. Overall, the article highlights the potential of PNR with MCL for investigation of soft matter samples.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。