Shack-Hartmann波前传感:时间分辨测量小型脆性试样动态断裂过程中应力强度的新方法
Shack-Hartmann wavefront sensing: A new approach to time-resolved measurement of stress intensity during dynamic fracture of small brittle specimens
AI总结:
本文提出用SHWFS替代DGS,以微米级空间和亚微秒时间分辨率测量毫米级脆性试样动态断裂的表面斜率,并提取表观应力强度因子演化。
摘要:
应力强度因子对于理解裂纹萌生和扩展十分重要。由于其无法直接测量,应力强度因子的表征依赖于对裂纹尖端周围变形的测量。对于脆性材料的动态断裂而言,这类测量颇具挑战性,因为变形很小,而裂纹尖端速度可能很高(>1 km/s)。数字梯度传感(DGS)能够以亚微秒时间分辨率对表面变形进行全场测量,但它仅限于厘米尺度试样,且空间分辨率仅约为1 mm。这限制了其测量裂纹尖端附近变形的能力。在这里,我们展示了Shack-Hartmann波前传感(SHWFS)作为DGS替代方案,在测量毫米尺度试样动态脆性断裂期间表面变形方面的潜力。以一种商用玻璃陶瓷作为示例材料,我们证明了SHWFS能够以微米尺度空间分辨率和亚微秒时间分辨率,测量毫米尺度试样上由扩展裂纹引起的表面斜率演化。SHWFS装置还具有比典型DGS装置物理结构更紧凑的额外优势。我们通过将SHWFS测量结果与裂纹尖端周围表面斜率的解析预测和相场模拟进行比较,验证了这些测量。随后,将表面斜率测量结果拟合到渐近裂纹尖端场解,我们提取了与扩展裂纹尖端相关的表观应力强度因子的演化。最后,我们讨论了该技术未来潜在的改进,以及其紧凑性如何能够促成与包括X射线相衬成像(XPCI)在内的其他表征技术集成,从而实现多模态表征。
英文摘要:
The stress intensity factor is important for understanding crack initiation and propagation. Because it cannot be measured directly, the characterization of the stress intensity factor relies on the measurement of deformation around a crack tip. Such measurements are challenging for dynamic fracture of brittle materials where the deformation is small and the crack tip velocity can be high (>1 km/s). Digital gradient sensing (DGS) is capable of full-field measurement of surface deformation with sub-microsecond temporal resolution, but it is limited to centimeter-scale specimens and has a spatial resolution of only $\sim 1$mm. This limits its ability to measure deformations close to the crack tip. Here, we demonstrate the potential of Shack-Hartmann wavefront sensing (SHWFS), as an alternative to DGS, for measuring surface deformation during dynamic brittle fracture of millimeter-scale specimens. Using an commercial glass ceramic as an example material, we demonstrate the capability of SHWFS to measure the surface slope evolution induced by a propagating crack on millimeter-scale specimens with a micrometer-scale spatial resolution and a sub-microsecond temporal resolution. The SHWFS apparatus has the additional advantage of being physically more compact than a typical DGS apparatus. We verify our SHWFS measurements by comparing them with analytical predictions and phase-field simulations of the surface slope around a crack tip. Then, fitting the surface slope measurements to the asymptotic crack-tip field solution, we extract the evolution of the apparent stress intensity factor associated with the propagating crack tip. We conclude by discussing potential future enhancements of this technique and how its compactness could enable the integration with other characterization techniques including x-ray phase-contrast imaging (XPCI) toward a multi-modal characterization.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。