AI总结:

本文针对单量子点器件确定性制备的对准精度问题,对比评估PL、CL成像及无标记原位电子束光刻三类定位方法的实际定位误差,明确了图像处理与制备流程对最终精度的影响。

摘要:

高效量子光源的实现依赖于将自组装量子点(QD)以高空间定位精度集成到光子纳米结构中。本工作中,我们对量子点定位精度开展了全面研究,涉及两类基于标记的量子点定位技术——光致发光(PL)成像与阴极发光(CL)成像,以及无标记原位电子束光刻(in-situ EBL)技术。我们采用了四种PL成像配置结合三种不同图像处理方法,并将其与CL成像进行对比。我们基于PL和CL图像处理得到的量子点坐标制备圆形台面结构,以评估最终定位精度。结果显示,PL成像对应的量子点相对于台面中心的最终位置偏移为μₓ=(-40±58) nm、μᵧ=(-39±85) nm,CL成像对应的偏移为μₓ=(-39±30) nm、μᵧ=(25±77) nm,二者与in-situ EBL方法得到的偏移μₓ=(20±40) nm、μᵧ=(-14±39) nm处于可比水平。我们讨论了观测到的偏移的可能成因,这些偏移显著大于直接对无结构晶圆上的量子点发光成像得到的量子点定位不确定度。本研究凸显了图像处理技术及后续制备流程对置于光子纳米结构内的量子点最终定位精度的影响。

英文摘要:

The realization of efficient quantum light sources relies on the integration of self-assembled quantum dots (QDs) into photonic nanostructures with high spatial positioning accuracy. In this work, we present a comprehensive investigation of the QD position accuracy, obtained using two marker-based QD positioning techniques, photoluminescence (PL) and cathodoluminescence (CL) imaging, as well as using a marker-free in-situ electron beam lithography (in-situ EBL) technique. We employ four PL imaging configurations with three different image processing approaches and compare them with CL imaging. We fabricate circular mesa structures based on the obtained QD coordinates from both PL and CL image processing to evaluate the final positioning accuracy. This yields final position offset of the QD relative to the mesa center of $μ_x$ = (-40$\pm$58) nm and $μ_y$ = (-39$\pm$85) nm with PL imaging and $μ_x$ = (-39$\pm$30) nm and $μ_y$ = (25$\pm$77) nm with CL imaging, which are comparable to the offset $μ_x$ = (20$\pm$40) nm and $μ_y$ = (-14$\pm$39) nm obtained using the in-situ EBL method. We discuss the possible causes of the observed offsets, which are significantly larger than the QD localization uncertainty obtained from simply imaging the QD light emission from an unstructured wafer. Our study highlights the influences of the image processing technique and the subsequent fabrication process on the final positioning accuracy for a QD placed inside a photonic nanostructure.