arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2309.12191eess.SPphysics.ins-det
收藏

超声速度与LiFePO$_4$方形电芯健康状态的相关性探究

Exploring the Correlation Between Ultrasound Speed and the State of Health of LiFePO$_4$ Prismatic Cells

Shengyuan Zhang, Peng Zuo, Xuesong Yin, Zheng Fan

AI总结:

针对在用电池健康状态检测难的问题,本研究发现LFP方形电芯超声速度随容量衰减降低,通过多孔介质波传播数值模拟解释相关性,指出粘结剂刚度下降是主因,为超声SoH估算提供新见解。

摘要:

电动汽车(EVs)已成为热门交通方式,其性能取决于所搭载锂离子电池的老化程度。然而,测定在用电池的容量保持率既困难又耗时,因此亟需一种快速可靠的健康状态(SoH)检测方法。超声检测技术因高效、便携、无损的特点极具应用前景。本研究证实,LFP方形电芯的超声速度会随容量衰减而降低。我们通过描述多孔介质中波传播的数值模拟解释了这一相关性,提出粘结剂刚度下降可能是电池老化过程中超声速度变化的主要原因。该研究为超声SoH估算技术提供了新见解。

英文摘要:

Electric vehicles (EVs) have become a popular mode of transportation, with their performance depending on the ageing of the Li-ion batteries used to power them. However, it can be challenging and time-consuming to determine the capacity retention of a battery in service. A rapid and reliable testing method for state of health (SoH) determination is desired. Ultrasonic testing techniques are promising due to their efficient, portable, and non-destructive features. In this study, we demonstrate that ultrasonic speed decreases with the degradation of the capacity of an LFP prismatic cell. We explain this correlation through numerical simulation, which describes wave propagation in porous media. We propose that the reduction of binder stiffness can be a primary cause of the change in ultrasonic speed during battery ageing. This work brings new insights into ultrasonic SoH estimation techniques.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑