基于TDLAS的铯原子浓度检测系统的设计与测试
Design and Testing of Cesium Atomic Concentration Detection System Based on TDLAS
AI总结:
本文针对NNBI和CRAFT项目,基于TDLAS技术利用852.1nm吸收峰设计了铯原子浓度检测系统,通过铯池实验验证了其检测范围和分辨率,为定量测量负离子源内的铯浓度提供了有效方法。
摘要:
为了更好地建设带有负离子源的中性束注入器(NNBI),针对聚变技术综合研究设施(CRAFT)开展了关键技术的预先研究。向负离子源中注入铯是获得所需负氢离子的前提条件。离子源的性能在很大程度上取决于源内的铯状态。在等离子体开启和关闭期间(真空阶段)定量测量源内的铯量是非常必要的。本文利用铯原子在852.1nm附近的吸收峰,构建了基于可调谐二极管激光吸收光谱(TDLAS)技术的铯原子浓度检测系统。开展了基于铯池的测试实验,获得了不同温度下铯浓度的变化曲线。实验结果表明:系统检测范围在5*10E6-2.5*10E7个/cm3以内,系统分辨率优于1*10E6个/cm3。
英文摘要:
In order to better build the Neutral Beam Injector with Negative Ion Source (NNBI), the pre-research on key technologies has been carried out for the Comprehensive Research Facility for Fusion Technology (CRAFT). Cesium seeding into negative-ion sources is a prerequisite to obtain the required negative hydrogen ion. The performance of ion source largely depends on the cesium conditions in the source. It is very necessary to quantitatively measure the amount of cesium in the source during the plasma on and off periods (vacuum stage). This article uses the absorption peak of cesium atoms near 852.1nm to build a cesium atom concentration detection system based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology. The test experiment based on the cesium cell is carried out, obtained the variation curve of cesium concentration at different temperatures. The experimental results indicate that: the system detection range is within 5*10E6-2.5*10E7 pieces/cm3 and the system resolution better than 1*10E6 pieces/cm3.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。