从少量平面X射线重建CT及其在低资源放疗中的应用

CT Reconstruction from Few Planar X-rays with Application towards Low-resource Radiotherapy

Rice University(莱斯大学);University of Texas MD Anderson Cancer Center(德克萨斯大学MD安德森癌症中心)

Yiran Sun, Tucker Netherton, Laurence Court, Ashok Veeraraghavan, Guha Balakrishnan

AI总结:

提出基于神经隐式表示的深度生成模型,从少量平面X射线重建CT体积,在放疗计划等临床应用中剂量误差<1%,并在公开数据集上优于现有基线。

摘要:

CT扫描是许多临床疾病的护理标准,也是外照射放疗等治疗所必需的。不幸的是,由于成本原因,CT扫描仪在低和中等资源环境中非常罕见。相比之下,平面X射线摄影设备要普遍得多,但只能提供3D解剖结构的有限2D观察。在这项工作中,我们提出了一种方法,利用先验数据分布从少量(<5)平面X射线观察生成CT体积,并首次对这种重建算法在临床应用(放疗计划)中进行评估。我们提出了一种深度生成模型,基于神经隐式表示的进展,从不同角度的少量输入平面X射线图像合成体积CT扫描。为了将生成任务集中在临床相关特征上,我们的模型还可以在训练期间利用解剖学指导(通过分割掩码)。我们在由我们方法重建的胸部CT上生成了2野对穿姑息放疗计划,并发现重建扫描上的等中心点辐射剂量与使用<=4个X射线视图在临床获取的CT上计算的剂量相比,误差<1%。此外,在公共LIDC肺部CT数据集上,我们的方法在标准像素和结构级指标(PSNR、SSIM、Dice分数)方面优于最近的稀疏CT重建基线。代码可在以下网址获取:https://github.com/wanderinrain/Xray2CT。

英文摘要:

CT scans are the standard-of-care for many clinical ailments, and are needed for treatments like external beam radiotherapy. Unfortunately, CT scanners are rare in low and mid-resource settings due to their costs. Planar X-ray radiography units, in comparison, are far more prevalent, but can only provide limited 2D observations of the 3D anatomy. In this work, we propose a method to generate CT volumes from few (<5) planar X-ray observations using a prior data distribution, and perform the first evaluation of such a reconstruction algorithm for a clinical application: radiotherapy planning. We propose a deep generative model, building on advances in neural implicit representations to synthesize volumetric CT scans from few input planar X-ray images at different angles. To focus the generation task on clinically-relevant features, our model can also leverage anatomical guidance during training (via segmentation masks). We generated 2-field opposed, palliative radiotherapy plans on thoracic CTs reconstructed by our method, and found that isocenter radiation dose on reconstructed scans have <1% error with respect to the dose calculated on clinically acquired CTs using <=4 X-ray views. In addition, our method is better than recent sparse CT reconstruction baselines in terms of standard pixel and structure-level metrics (PSNR, SSIM, Dice score) on the public LIDC lung CT dataset. Code is available at: https://github.com/wanderinrain/Xray2CT.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑