跨多种速度下使用腰部佩戴加速度计的步态事件检测与行程距离:自动化方法
Gait Event Detection and Travel Distance Using Waist-Worn Accelerometers across a Range of Speeds: Automated Approach
AI总结:
本文提出一种结合临床观察、机器学习步态检测和回归步长预测的新型校准方法,利用单个腰部佩戴加速度计,在多种步态速度下准确测量DMD儿童与正常对照的步态时空临床特征并估计行程距离。
摘要:
使用可穿戴加速度计进行基于社区的移动能力评估时,估计步态的时空临床特征(CFs),如步数和步长、步态持续时间、步频、步速和行程距离,是一个重要组成部分。然而,由于进行性丧失行走能力的杜氏肌营养不良症(DMD)患者在其可达到的步态速度范围内,加速度的模式和大小存在差异,因此难以对DMD个体的CFs进行准确的无监督计算机化测量。本文提出了一种新颖的校准方法。其旨在检测步数、估计步长并确定行程距离。该方法结合了临床观察、基于机器学习的步态检测和基于回归的步长预测。无论参与者的能力水平如何,该方法在DMD儿童和典型发育对照组(TDs)中均表现出高准确度。15名DMD儿童和15名TDs在佩戴位于身体重心附近的腰部基于手机的加速度计的情况下,通过10米或25米跑/走(10 MRW, 25 MRW)、100米跑/走(100 MRW)、6分钟步行(6 MWT)和自由步行(FW)评估,进行了跨越多种步态速度的监督临床测试。经过训练有素的临床评估员校准后,使用多步骤的基于机器学习的过程从加速度计数据中提取CFs,并将结果与真实观察数据进行比较。模型预测值与观察值在步数、行程距离和步长方面显示出强相关性。我们的研究结果表明,使用我们的方法校准至个体步态特征的单个腰部佩戴加速度计,能够准确测量CFs并估计DMD和TD同龄人在常见步态速度范围内的行程距离。
英文摘要:
Estimation of temporospatial clinical features of gait (CFs), such as step count and length, step duration, step frequency, gait speed, and distance traveled, is an important component of community-based mobility evaluation using wearable accelerometers. However, accurate unsupervised computerized measurement of CFs of individuals with Duchenne muscular dystrophy (DMD) who have progressive loss of ambulatory mobility is difficult due to differences in patterns and magnitudes of acceleration across their range of attainable gait velocities. This paper proposes a novel calibration method. It aims to detect steps, estimate stride lengths, and determine travel distance. The approach involves a combination of clinical observation, machine-learning-based step detection, and regression-based stride length prediction. The method demonstrates high accuracy in children with DMD and typically developing controls (TDs) regardless of the participant's level of ability. Fifteen children with DMD and fifteen TDs underwent supervised clinical testing across a range of gait speeds using 10 m or 25 m run/walk (10 MRW, 25 MRW), 100 m run/walk (100 MRW), 6-min walk (6 MWT), and free-walk (FW) evaluations while wearing a mobile-phone-based accelerometer at the waist near the body's center of mass. Following calibration by a trained clinical evaluator, CFs were extracted from the accelerometer data using a multi-step machine-learning-based process and the results were compared to ground-truth observation data. Model predictions vs. observed values for step counts, distance traveled, and step length showed a strong correlation. Our study findings indicate that a single waist-worn accelerometer calibrated to an individual's stride characteristics using our methods accurately measures CFs and estimates travel distances across a common range of gait speeds in both DMD and TD peers.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。