arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2307.03872eess.IVcs.AIcs.CVcs.LG
收藏

在数字病理学中使用银标准标签进行 Ki-67 评分的领域适应:迈向大规模部署的一步

Domain Adaptation using Silver Standard Labels for Ki-67 Scoring in Digital Pathology: A Step Closer to Widescale Deployment

Toronto Metropolitan University(多伦多都会大学);University of Toronto(多伦多大学);Princess Margaret Cancer Centre(玛嘉烈公主癌症中心);University Health Network(大学医疗网络)

Amanda Dy, Ngoc-Nhu Jennifer Nguyen, Seyed Hossein Mirjahanmardi, Melanie Dawe, Anthony Fyles, Wei Shi, Fei-Fei Liu, Dimitrios Androutsos, Susan Done, April Khademi

AI总结:

本文提出无监督生成目标域银标准标签的领域适应流程,并通过 SS+GS 训练策略提升 Ki-67 PI 评分跨域准确率与泛化性。

摘要:

为提高 Ki-67 PI 评分的客观性和效率,已有研究提出深度学习系统。挑战在于,尽管深度学习技术非常准确,但在应用于域外数据时会出现性能下降。这对临床转化是一项关键挑战,因为模型通常使用供应商可获得的数据进行训练,而这些数据并不来自目标领域。为应对这一挑战,本研究提出一种领域适应流程,该流程采用无监督框架在目标领域中生成银标准(伪)标签,并用其增强金标准(GS)源领域数据。研究在两种经过验证的 Ki-67 评分架构(UV-Net 和 piNET)上测试了五种训练方案:(1)SS Only:在目标银标准(SS)标签上训练;(2)GS Only:在源 GS 标签上训练;(3)Mixed:在目标 SS 标签和源 GS 标签上训练;(4)GS+SS:在源 GS 标签上训练并在目标 SS 标签上微调;以及本文提出的方法(5)SS+GS:在源 SS 标签上训练并在源 GS 标签上微调。与目标数据上的 GS Only 模型相比,SS+GS 方法取得了显著(p < 0.05)更高的 PI 准确率(95.9%)以及更一致的结果。对 t-SNE 图的分析表明,SS+GS 模型学习到的特征在源数据和目标数据之间更加一致,从而改善了泛化能力。所提出的流程提供了一种无需人工标注即可学习目标分布的高效方法,而医学图像的人工标注生成既耗时又昂贵。该框架可作为逐实验室校准方法应用于任何目标站点,以实现大规模部署。

英文摘要:

Deep learning systems have been proposed to improve the objectivity and efficiency of Ki- 67 PI scoring. The challenge is that while very accurate, deep learning techniques suffer from reduced performance when applied to out-of-domain data. This is a critical challenge for clinical translation, as models are typically trained using data available to the vendor, which is not from the target domain. To address this challenge, this study proposes a domain adaptation pipeline that employs an unsupervised framework to generate silver standard (pseudo) labels in the target domain, which is used to augment the gold standard (GS) source domain data. Five training regimes were tested on two validated Ki-67 scoring architectures (UV-Net and piNET), (1) SS Only: trained on target silver standard (SS) labels, (2) GS Only: trained on source GS labels, (3) Mixed: trained on target SS and source GS labels, (4) GS+SS: trained on source GS labels and fine-tuned on target SS labels, and our proposed method (5) SS+GS: trained on source SS labels and fine-tuned on source GS labels. The SS+GS method yielded significantly (p < 0.05) higher PI accuracy (95.9%) and more consistent results compared to the GS Only model on target data. Analysis of t-SNE plots showed features learned by the SS+GS models are more aligned for source and target data, resulting in improved generalization. The proposed pipeline provides an efficient method for learning the target distribution without manual annotations, which are time-consuming and costly to generate for medical images. This framework can be applied to any target site as a per-laboratory calibration method, for widescale deployment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑