使用贝叶斯方法结合参数估计与互补欠采样模式的基于模型的T1、T2*和质子密度映射
Model-based T1, T2* and Proton Density Mapping Using a Bayesian Approach with Parameter Estimation and Complementary Undersampling Patterns
AI总结:
提出一种名为AMP-PE的贝叶斯非线性近似消息传递框架,通过结合信号模型与稀疏先验实现定量MR图像的联合恢复与自动超参数估计,并确定了不同定量映射的最佳互补欠采样方案。
摘要:
目的:为实现定量MR图像联合恢复的自动超参数估计,我们提出了一种包含信号模型的重建问题贝叶斯公式。此外,我们研究了互补欠采样模式的使用,以确定定量MRI的最佳欠采样方案。理论:我们引入了一种新颖的非线性近似消息传递框架,称为“AMP-PE”,能够同时恢复分布参数和定量图。方法:我们采用可变翻转角多回波(VFA-ME)方法获取测量数据。回顾性和前瞻性欠采样方法均被用于通过变密度和Poisson-disk模式获取傅里叶测量数据。此外,我们广泛探索了各种欠采样方案,包含不同翻转角和/或回波时间下的互补模式。结果:AMP-PE采用基于模型的联合恢复策略,优于遵循解耦恢复策略的$l_1$范数最小化方法。与现有联合恢复方法的比较进一步证明了AMP-PE的优势结果。对于使用VFA-ME的定量$T_1$映射,在不同回波时间采用相同的k空间采样模式产生了最佳性能。而对于$T_2^*$和质子密度映射,在不同翻转角使用互补采样模式产生了最佳性能。结论:AMP-PE具备内置参数估计功能,可自然适用于具有不同采集协议和扫描仪的临床环境。它还通过结合来自MR信号模型和图像稀疏先验的信息来实现性能提升。
英文摘要:
Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the use of complementary undersampling patterns to determine optimal undersampling schemes for quantitative MRI. Theory: We introduce a novel nonlinear approximate message passing framework, referred to as ``AMP-PE'', that enables the simultaneous recovery of distribution parameters and quantitative maps. Methods: We employed the variable flip angle multi-echo (VFA-ME) method to acquire measurements. Both retrospective and prospective undersampling approaches were utilized to obtain Fourier measurements using variable-density and Poisson-disk patterns. Furthermore, we extensively explored various undersampling schemes, incorporating complementary patterns across different flip angles and/or echo times. Results: AMP-PE adopts a model-based joint recovery strategy, it outperforms the $l_1$-norm minimization approach that follows a decoupled recovery strategy. A comparison with an existing joint-recovery approach further demonstrates the advantageous outcomes of AMP-PE. For quantitative $T_1$ mapping using VFA-ME, employing identical k-space sampling patterns across different echo times produced the best performance. Whereas for $T_2^*$ and proton density mappings, using complementary sampling patterns across different flip angles yielded the best performance. Conclusion: AMP-PE is equipped with built-in parameter estimation, and works naturally in clinical settings with varying acquisition protocols and scanners. It also achieves improved performance by combining information from the MR signal model and the sparse prior on images.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。