使用 Latent Neural Ordinary Differential Equations 的实时全心脏机电仿真
Real-time whole-heart electromechanical simulations using Latent Neural Ordinary Differential Equations
AI总结:
提出基于LNODEs的全心脏机电代理模型,用400组3D-0D仿真和43个参数训练,实现单处理器300倍实时仿真及带不确定性量化的参数校准。
摘要:
心脏数字孪生提供了一个基于物理和生理学的框架,以实现预测性和个性化医疗。然而,高保真多尺度心脏模型由于其巨大的计算成本以及患者特异性个性化所需的大量模型评估,仍然是其被采用的障碍。基于人工智能的方法可以使快速且准确的全心脏数字孪生的创建变得可行。在本研究中,我们使用 Latent Neural Ordinary Differential Equations(LNODEs,潜空间神经常微分方程)来学习一名心力衰竭患者的时间压力-容积动力学。我们基于 LNODEs 的代理模型由400个3D-0D全心脏闭环机电仿真训练得到,同时考虑了43个模型参数,这些参数描述了从单细胞到整个器官以及心血管血流动力学的内容。训练后的 LNODEs 通过一个前馈全连接人工神经网络在潜空间中提供了3D-0D模型的紧凑且高效的表示,该网络保留3个隐藏层,每层13个神经元,并允许在标准笔记本电脑的单个处理器上进行心脏功能的300倍实时数值仿真。该代理模型被用于在3小时计算内执行全局敏感性分析和带不确定性量化的鲁棒参数估计,且仍然在单个处理器上完成。我们匹配了 LNODEs 在训练阶段未见过的压力和容积时间轨迹,并校准了4到11个模型参数,同时给出了它们的后验分布。本文介绍了文献中可用的最先进的心脏功能代理模型,并为心脏数字孪生中的参数校准开辟了重要的新途径。
英文摘要:
Cardiac digital twins provide a physics and physiology informed framework to deliver predictive and personalized medicine. However, high-fidelity multi-scale cardiac models remain a barrier to adoption due to their extensive computational costs and the high number of model evaluations needed for patient-specific personalization. Artificial Intelligence-based methods can make the creation of fast and accurate whole-heart digital twins feasible. In this work, we use Latent Neural Ordinary Differential Equations (LNODEs) to learn the temporal pressure-volume dynamics of a heart failure patient. Our surrogate model based on LNODEs is trained from 400 3D-0D whole-heart closed-loop electromechanical simulations while accounting for 43 model parameters, describing single cell through to whole organ and cardiovascular hemodynamics. The trained LNODEs provides a compact and efficient representation of the 3D-0D model in a latent space by means of a feedforward fully-connected Artificial Neural Network that retains 3 hidden layers with 13 neurons per layer and allows for 300x real-time numerical simulations of the cardiac function on a single processor of a standard laptop. This surrogate model is employed to perform global sensitivity analysis and robust parameter estimation with uncertainty quantification in 3 hours of computations, still on a single processor. We match pressure and volume time traces unseen by the LNODEs during the training phase and we calibrate 4 to 11 model parameters while also providing their posterior distribution. This paper introduces the most advanced surrogate model of cardiac function available in the literature and opens new important venues for parameter calibration in cardiac digital twins.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。