arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2305.07103physics.opticsphysics.ins-det
收藏

关于将消费级360度相机用作科学应用辐射计的研究

On the use of a consumer-grade 360-degree camera as a radiometer for scientific applications

Raphaël Larouche, Simon Lambert-Girard, Christian Katlein, Sabine Marty, Edouard Leymarie, Simon Thibault, Marcel Babin

AI总结:

本文提出将消费级360度相机校准为科学辐射计的方法,涵盖线性度、几何、光谱响应和绝对辐射亮度等校准,并通过与C-OPS对比验证精度,为低成本、易获取的辐射亮度测量提供新途径。

摘要:

复杂鱼眼相机系统小型化能力的提升,最近促使许多紧凑型360度相机进入消费技术市场。这些相机主要面向休闲摄影设计,但多家制造商已决定允许用户访问原始图像以便进一步编辑,从而在传感器层面提供可直接用于绝对光量化的数据。在本研究中,我们展示了将消费级360度相机仔细校准用于辐射测量的方法。这些方法包括线性度分析、几何校准、像面照度衰减评估、光谱响应测定、绝对光谱辐射亮度校准、浸没因子测定以及暗帧分析。校准的准确性通过一项真实世界实验得到验证,该实验将天空辐射亮度测量结果与同址部署的紧凑型光学剖面系统(C-OPS,Biospherical Instruments Inc.)进行比较,得到的平均无偏百分比差异小于21.1%。利用光子转移技术,我们计算出这款由两个鱼眼镜头组成、空气中视场角为182°(水中为152°)的相机在其三个光谱通道中的检测限至少为4.6 × 10⁻⁷ W·sr⁻¹·m⁻²·nm⁻¹。这项技术只要妥善存储校准数据,就可能惠及多个科学领域中关注辐射几何光场研究的研究人员。尽管其中一些辐射校准方法较为复杂或成本较高,但本工作为易用、廉价且可获取的辐射亮度相机开辟了可能性。

英文摘要:

Improved miniaturization capabilities for complex fisheye camera systems have recently led to the introduction of many compact 360-degree cameras on the consumer technology market. Designed primarily for recreational photography, several manufacturers have decided to allow users access to raw imagery for further editing flexibility, thereby offering data at sensor level that can be directly exploited for absolute-light quantification. In this study, we demonstrate methodologies to carefully calibrate a consumer-grade 360-degree camera for radiometry use. The methods include linearity analysis, geometric calibration, assessment of the illumination fall-off across the image plane, spectral-response determination, absolute spectral-radiance calibration, immersion factor determination and dark-frame analysis. Accuracy of the calibration was validated by a real-world experiment comparing sky radiance measurements with a co-localized Compact Optical Profiling System (C-OPS, Biospherical Instruments Inc.), which gave mean unbiased percentage differences of less than 21.1 %. Using the photon-transfer technique, we calculated that this camera consisting of two fisheyes with a 182$^\circ$ field of view in air (152$^\circ$ in water) has a limit of detection of at least $4.6 \times 10^{-7}$ $\mathrm{W \cdot sr^{-1} \cdot m^{-2} \cdot nm^{-1}}$ in its three spectral channels. This technology, with properly stored calibration data, may benefit researchers from multiple scientific areas interested in radiometric geometric light-field study. While some of these radiometric calibration methods are complex or costly, this work opens up possibilities for easy-to-use, inexpensive, and accessible radiance cameras.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑