arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2304.14919eess.SPcs.LG
收藏

ScatterFormer:用于患者独立的多光谱癫痫样放电检测的局部不变散射Transformer

ScatterFormer: Locally-Invariant Scattering Transformer for Patient-Independent Multispectral Detection of Epileptiform Discharges

Research Institute of Intelligent and Complex Systems, Fudan University(复旦大学智能与复杂系统研究院);State Key Laboratory of Medical Neurobiology, Fudan University(复旦大学医学神经生物学国家重点实验室);MOE Frontiers Center for Brain Science, Fudan University(复旦大学脑科学前沿科学中心);Institutes of Brain Science, Fudan University(复旦大学脑科学研究院);Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University(复旦大学脑启发智能科学技术研究院);Shanghai Artificial Intelligence Laboratory(上海人工智能实验室)

Ruizhe Zheng, Jun Li, Yi Wang, Tian Luo, Yuguo Yu

AI总结:

针对脑电癫痫活动检测中个体差异导致的精准检测难题,提出基于不变散射变换的分层ScatterFormer模型,通过解耦频率感知注意力捕捉高频特征,在两类癫痫检测任务上均取得优于现有方法的性能。

摘要:

基于连续脑电图(cEEG)视觉频谱表示的患者独立癫痫活动检测已被广泛用于癫痫诊断。然而,由于受试者、通道和时间点之间存在细微差异,精准检测仍然是一项相当大的挑战。因此,捕捉与高频纹理信息相关的脑电模式的细粒度判别特征这一问题仍有待解决。在本研究中,我们提出了散射Transformer(ScatterFormer),这是一种基于不变散射变换的分层Transformer,专门用于关注细微特征。具体而言,解耦的频率感知注意力(FAA)使Transformer能够捕捉具有临床信息价值的高频成分,基于多通道脑电信号的视觉编码提供了一种新颖的临床可解释性。我们在两项不同的癫痫样检测任务上进行了评估,验证了该方法的有效性。我们提出的模型在 Rolandic 癫痫患者中达到了98.14%的中位AUCROC和96.39%的准确率。在新生儿癫痫发作检测基准上,其平均AUCROC比现有最优方法高出9%。

英文摘要:

Patient-independent detection of epileptic activities based on visual spectral representation of continuous EEG (cEEG) has been widely used for diagnosing epilepsy. However, precise detection remains a considerable challenge due to subtle variabilities across subjects, channels and time points. Thus, capturing fine-grained, discriminative features of EEG patterns, which is associated with high-frequency textural information, is yet to be resolved. In this work, we propose Scattering Transformer (ScatterFormer), an invariant scattering transform-based hierarchical Transformer that specifically pays attention to subtle features. In particular, the disentangled frequency-aware attention (FAA) enables the Transformer to capture clinically informative high-frequency components, offering a novel clinical explainability based on visual encoding of multichannel EEG signals. Evaluations on two distinct tasks of epileptiform detection demonstrate the effectiveness our method. Our proposed model achieves median AUCROC and accuracy of 98.14%, 96.39% in patients with Rolandic epilepsy. On a neonatal seizure detection benchmark, it outperforms the state-of-the-art by 9% in terms of average AUCROC.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑