arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2303.09130physics.ins-detastro-ph.IM
收藏

EUCLID NISP grisms飞行模型性能

The EUCLID NISP grisms flight models performance

Anne Costille, A. Caillat, C. Rossin, S. Pascal, P. Sanchez, R. Barette, P. Laurent, B. Foulon, C. Pariès

摘要:

欧空局EUCLID任务将于2020年启动,以了解导致宇宙加速膨胀的暗能量的性质,并绘制暗物质的几何形状。这张地图将研究距离移动关系和宇宙结构的演变,这要归功于两台仪器:NISP和VIS。NISP(近红外分光光度计)在近红外光谱范围(0.9-2 $μ$ m)内工作,具有两种观察模式:用于使用宽带滤光片获取图像的光度模式,以及用于在检测器上获取无缝分散图像的光谱模式。光谱模式使用四个低分辨率的光栅来覆盖两个光谱范围:三个“红色”光栅用于1250- 1850 nm范围,具有三个不同的方向,一个“蓝色”光栅用于920- 1300 nm范围。NISP光栅是结合了四种主要光学功能的复杂光学组件:棱镜函数(色散而没有第一衍射级的光束偏移),由沉积在棱镜的第一面上的多层滤光器完成的光谱滤光器,以选择光谱带通,由棱镜的弯曲滤波器面(曲率半径为10 μ m)完成的聚焦功能和由光栅完成的光谱波前校正,其中凹槽路径既不平行也不直。这些组件的开发工作已经在马赛天文物理学实验室(LAM)开始了10年,并与项目阶段相关联:已经开发了原型来证明可行性,然后是工程和鉴定模型来验证组件的光学和机械性能,最后是飞行模型已经制造和测试,并将安装在NISP仪器上。在本文中,我们提出的光学性能的四个EUCLID NISP光栅飞行模型,其特征在于在LAM:波前误差,光谱传输和光栅槽的轮廓。描述了用于表征这些特定光学元件的测试装置和方法。对实验结果的分析表明,NISP的GRISMS飞行模型在光谱带通效率优于70%,表面波前误差优于30 nm RMS的技术指标范围内。在随机测试和真空低温测试中,组件经受了高达11.6g RMS的振动合格水平,低至130 K,并测量了传输中的光学质量。EUCLID grisms飞行模型已于2017年11月交付给NISP项目,此前在LAM进行了测试活动,证明符合规范。

英文摘要:

ESA EUCLID mission will be launched in 2020 to understand the nature of the dark energy responsible of the accelerated expansion of the Universe and to map the geometry of the dark matter. The map will investigate the distanceredshift relationship and the evolution of cosmic structures thanks to two instruments: the NISP and the VIS. The NISP (Near Infrared Spectro-Photometer) is operating in the near-IR spectral range (0.9-2$μ$m) with two observing modes: the photometric mode for the acquisition of images with broad band filters, and the spectroscopic mode for the acquisition of slitless dispersed images on the detectors. The spectroscopic mode uses four low resolution grisms to cover two spectral ranges: three ''red'' grisms for 1250-1850nm range, with three different orientations, and one ''blue'' grism for 920- 1300nm range. The NISP grisms are complex optical components combining four main optical functions: a grism function (dispersion without beam deviation of the first diffracted order) done by the grating on the prism hypotenuse, a spectral filter done by a multilayer filter deposited on the first face of the prism to select the spectral bandpass, a focus function done by the curved filter face of the prism (curvature radius of 10m) and a spectral wavefront correction done by the grating which grooves paths are nor parallel, neither straight. The development of these components have been started since 10 years at the Laboratoire d'Astrophysique de Marseille (LAM) and was linked to the project phases: prototypes have been developed to demonstrate the feasibility, then engineering and qualification models to validate the optical and mechanical performance of the component, finally the flight models have been manufactured and tested and will be installed on NISP instrument. In this paper, we present the optical performance of the four EUCLID NISP grisms flight models characterized at LAM: wavefront error, spectral transmission and grating groove profiles. The test devices and the methods developed for the characterization of these specific optical components are described. The analysis of the test results have shown that the grisms flight models for NISP are within specifications with an efficiency better than 70% on the spectral bandpass and a wavefront error on surfaces better than 30nm RMS. The components have withstood vibration qualification level up to 11.6g RMS in random test and vacuum cryogenics test down to 130K with measurement of optical quality in transmission. The EUCLID grisms flight models have been delivered to NISP project in November 2017 after the test campaign done at LAM that has demonstrated the compliance to the specifications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑