检验标准差和RMS误差应用于眼动时间序列的统计假设:人眼和人工眼的比较

Checking the Statistical Assumptions Underlying the Application of the Standard Deviation and RMS Error to Eye-Movement Time Series: A Comparison between Human and Artificial Eyes

Lee Friedman, Timothy Hanson, Hal S. Stern, Oleg V. Komogortsev

摘要:

空间精度通常使用眼睛位置信号的标准偏差(SD)或固定期间样本间差异(StoS)信号的RMS来测量。由于这两种测量方法都是从应用于时间序列的统计理论中产生的,因此伴随着它们的使用,存在某些统计假设。很明显,SD在应用于单峰分布时是最有用的。这两种测量都假设平稳性,这意味着信号的统计特性随时间推移而稳定。这两个度量都假设信号的样本是独立的。自相关的存在表明时间序列中的样本不是独立的。我们用来自两项研究的多次注视测试了这些假设,一个公开的数据集,包括人眼和人工眼(“HA数据集”,N=224次注视),以及来自我们实验室的4名受试者的数据(“TXstate”,N=37次注视)。许多位置信号分布是多模态的(HA:中位数= 32%,TX状态:中位数=100%)。没有固定位置信号。所有位置信号在统计学上显著自相关(p < 0:01)。因此,任何固定均不符合SD的统计假设。所有StoS信号均为单峰。一些StoS信号是稳定的(HA:34%,TX状态:24%)。几乎所有的StoS信号在统计学上显著自相关(p < 0:01)。对于TXstate,37次固定中有3次符合所有假设。因此,一般不符合RMS的统计假设。这些假设的普遍失败使人们对SD或RMS-StoS作为眼动仪精度指标的适当性提出了质疑。

英文摘要:

Spatial precision is often measured using the standard deviation (SD) of the eye position signal or the RMS of the sample-to-sample differences (StoS) signal during fixation. As both measures emerge from statistical theory applied to time-series, there are certain statistical assumptions that accompany their use. It is intuitively obvious that the SD is most useful when applied to unimodal distributions. Both measures assume stationarity, which means that the statistical properties of the signals are stable over time. Both metrics assume the samples of the signals are independent. The presence of autocorrelation indicates that the samples in the time series are not independent. We tested these assumptions with multiple fixations from two studies, a publicly available dataset that included both human and artificial eyes ("HA Dataset", N=224 fixations), and data from our laboratory of 4 subjects ("TXstate", N=37 fixations). Many position signal distributions were multimodal (HA: median=32%, TXstate: median=100%). No fixation position signals were stationary. All position signals were statistically significantly autocorrelated (p < 0:01). Thus, the statistical assumptions of the SD were not met for any fixation. All StoS signals were unimodal. Some StoS signals were stationary (HA: 34%, TXstate: 24%). Almost all StoS signals were statistically significantly autocorrelated (p < 0:01). For TXstate, 3 of 37 fixations met all assumptions. Thus, the statistical assumptions of the RMS were generally not met. The general failure of these assumptions calls into question the appropriateness of the SD or the RMS-StoS as metrics of precision for eye-trackers.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑