arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2302.12180astro-ph.IMphysics.ins-det
收藏

面向神冈引力波探测器(KAGRA)的先进光子校准器研制

Development of advanced photon calibrator for Kamioka gravitational wave detector (KAGRA)

National Central University(中央大学);Academia Sinica(中央研究院);High Energy Accelerator Research Organization (KEK)(高能加速器研究机构);The University of Tokyo(东京大学);Taiwan International Graduate Program(台湾国际研究生计划);University of Toyama(富山大学);SOKENDAI (The Graduate University for Advanced Studies)(综合研究大学院大学);Osaka City University(大阪市立大学);JAXA Institute of Space and Astronautical Science(宇宙科学研究所);Osaka Metropolitan University(大阪公立大学)
Y. Inoue, B. H. Hsieh, K. H. Chen, Y. K. Chu, K. Ito, C. Kozakai, T. Shishido, Y. Tomigami, T. Akutsu, S. Haino, K. Izumi, T. Kajita, N. Kanda, C. S. Lin, F. K.… 展开作者

Y. Inoue, B. H. Hsieh, K. H. Chen, Y. K. Chu, K. Ito, C. Kozakai, T. Shishido, Y. Tomigami, T. Akutsu, S. Haino, K. Izumi, T. Kajita, N. Kanda, C. S. Lin, F. K. Lin, Y. Moriwaki, W. Ogaki, H. F. Pang, T. Sawada, T. Tomaru, T. Suzuki, S. Tsuchida, T. Ushiba, T. Washimi, T. Yamamoto, T. Yokozawa

AI总结:

本文研制了KAGRA的先进光子校准器,通过高功率激光、功率稳定和远程光束位置控制三项改进,将总系统误差降至2.0 /%,实现了kHz频段探测器响应的精确校准。

摘要:

神冈引力波探测器(KAGRA)低温引力波天文台已开始与全球引力波探测器网络进行联合观测。精确校准探测器响应对于准确估计引力波源参数至关重要。光子校准器是激光干涉仪引力波天文台、Virgo和KAGRA使用的重要校准工具,并在2020年4月与德国GEO600进行的联合观测3中得到应用。本文中,KAGRA实施了三项关键改进:高功率激光器、功率稳定系统和远程光束位置控制。KAGRA采用一台20 W激光器,将其分为两束光注入镜面。通过使用高功率激光器,可以校准探测器在kHz频率下的响应。为独立控制每束激光的功率,安装了光学跟随伺服系统用于功率稳定。光子校准器光束位置的光路通过微型电机进行控制,从而能够表征探测器的旋转响应。此外,安装了长焦相机和象限光电探测器来监测光束位置,并实现了光束位置控制以优化镜面响应。本文讨论了与相对功率噪声测量相关的统计误差。我们还讨论了与光子校准器功率校准模型相关的系统误差,以及使用有限元分析对弹性形变效应进行的模拟。最终,我们成功地将光子校准器引入的总系统误差降低至2.0 /%。

英文摘要:

The Kamioka Gravitational wave detector (KAGRA) cryogenic gravitational-wave observatory has commenced joint observations with the worldwide gravitational wave detector network. Precise calibration of the detector response is essential for accurately estimating parameters of gravitational wave sources. A photon calibrator is a crucial calibration tool used in laser interferometer gravitational-wave observatory, Virgo, and KAGRA, and it was utilized in joint observation 3 with GEO600 in Germany in April 2020. In this paper, KAGRA implemented three key enhancements: a high-power laser, a power stabilization system, and remote beam position control. KAGRA employs a 20 W laser divided into two beams that are injected onto the mirror surface. By utilizing a high-power laser, the response of the detector at kHz frequencies can be calibrated. To independently control the power of each laser beam, an optical follower servo was installed for power stabilization. The optical path of the photon calibrator beam positions was controlled using pico-motors, allowing for the characterization of the detector rotation response. Additionally, a telephoto camera and quadrant photodetectors were installed to monitor beam positions, and beam position control was implemented to optimize the mirror response. In this paper, we discuss the statistical errors associated with the measurement of relative power noise. We also address systematic errors related to the power calibration model of the photon calibrator and the simulation of elastic deformation effects using finite element analysis. Ultimately, we have successfully reduced the total systematic error from the photon calibrator to 2.0 /%.