arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2302.11462cond-mat.mtrl-sci
收藏

揭示透射电子显微镜中温度对磁振子漫散射探测的影响

Unveiling the impact of temperature on magnon diffuse scattering detection in the transmission electron microscope

José Ángel Castellanos-Reyes, Paul Zeiger, Anders Bergman, Demie Kepaptsoglou, Quentin M. Ramasse, Juan Carlos Idrobo, Ján Rusz

AI总结:

本文利用冻结声子和冻结磁振子多层法研究温度对体心立方Fe中磁振子漫散射与热漫散射的影响,揭示原子振动使MDS信号由线性增长转为非线性并出现主导峰,且信噪比分析表明MDS在可实现的实验条件下可被统计显著地探测。

摘要:

得益于电子能量损失谱学近年来的技术进步,磁振子漫散射(MDS)信号可以在扫描透射电子显微镜(STEM)中以高空间分辨率进行研究。然而,在STEM中探测MDS信号具有挑战性,因为它们与更强的热漫散射(TDS)信号重叠。在300 K的体心立方Fe中,大于或与TDS相当的MDS信号出现在中心布拉格盘下方,进入当前无法到达的能量损失区域。因此,为了在STEM中探测MDS,有必要找到能够分离TDS和MDS信号的条件。由于磁振子信号和声子信号具有不同的热特征,温度可能是一个关键因素。在这项工作中,我们使用冻结声子和冻结磁振子多层法,研究了温度对体心立方Fe中MDS和TDS的影响——考虑中心布拉格盘外的探测器和固定的会聚电子探针。我们的研究表明,忽略原子振动的影响会导致MDS信号近似线性增长,直到Fe的居里温度,之后其变化较小。由于动力学衍射,MDS信号表现出交替行为,而不是随厚度单调增加。通过复原子静电势纳入原子振动的影响,使MDS信号的线性增长转变为非线性行为,在1100 K时对厚度为16.072 nm的样品表现出一个主导峰。相比之下,TDS信号比MDS信号更线性地增长,但仍表现出明显的动力学衍射效应。对信噪比(SNR)的分析表明,在可实现的测量条件和采集时间下,MDS信号可以对总散射强度产生统计上显著的贡献。

英文摘要:

Magnon diffuse scattering (MDS) signals could be studied with high spatial resolution in scanning transmission electron microscopy (STEM), thanks to recent technological progress in electron energy loss spectroscopy. However, detecting MDS signals in STEM is challenging due to their overlap with stronger thermal diffuse scattering (TDS) signals. In bcc Fe at 300 K, MDS signals greater than or comparable to TDS signals occur under the central Bragg disk, into a currently inaccesible energy-loss region. Therefore, to detect MDS in STEM, it is necessary to find conditions in which TDS and MDS signals can be separated. Temperature may be a key factor due to the distinct thermal signatures of magnon and phonon signals. In this work, we present a study on the effects of temperature on MDS and TDS in bcc Fe -- considering a detector outside the central Bragg disk and a fixed convergent electron probe -- using the frozen phonon and frozen magnon multislice methods. Our study reveals that neglecting the effects of atomic vibrations causes the MDS signal to grow approximately linearly up to the Curie temperature of Fe, after which it exhibits less variation. The MDS signal displays an alternating behavior due to dynamical diffraction, instead of increasing monotonically as a function of thickness. Including the effects of atomic vibrations through a complex atomic electrostatic potential causes the linear growth of the MDS signal to change to a non-linear behavior that exhibits a predominant peak for a sample of thickness 16.072 nm at 1100 K. In contrast, the TDS signal grows more linearly than the MDS signal but still exhibits appreciable dynamical diffraction effects. An analysis of the signal-to-noise ratio (SNR) shows that the MDS signal can be a statistically significant contribution to the total scattering intensity under realizable measurement conditions and acquisition times.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑