arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2302.07556quant-phphysics.ins-det
收藏

迈向轴子搜索的脉冲单微波光子探测器

Stepping closer to pulsed single microwave photon detectors for axions search

A. D'Elia, A. Rettaroli, S. Tocci, D. Babusci, C. Barone, M. Beretta, B. Buonomo, F. Chiarello, N. Chikhi, D. Di Gioacchino, G. Felici, G. Filatrella, M. Fistul… 展开作者

A. D'Elia, A. Rettaroli, S. Tocci, D. Babusci, C. Barone, M. Beretta, B. Buonomo, F. Chiarello, N. Chikhi, D. Di Gioacchino, G. Felici, G. Filatrella, M. Fistul, L. G. Foggetta, C. Gatti, E. Il'ichev, C. Ligi, M. Lisitskiy, G. Maccarrone, F. Mattioli, G. Oelsner, S. Pagano, L. Piersanti, B. Ruggiero, G. Torrioli, A. Zagoskin

摘要:

轴子探测需要达到单光子极限的极限灵敏度。在微波区,这对应于yJ范围内的能量。这种极端的灵敏度必须与极低的暗计数率相结合,因为轴子转换为微波光子的概率应该非常低。为了面对这个复杂的任务,我们遵循了两种有希望的方法,这两种方法都依赖于使用基于约瑟夫森效应的超导设备。第一种是使用单个约瑟夫森结(JJ)作为开关检测器(即利用微波光子存在下的超导到正常态的转变)。我们设计了一个由共面波导和电流偏置约瑟夫森结组成的器件。我们测试了它的效率脉冲(脉冲持续时间10纳秒)微波信号,因为这种配置更接近于一个实际的轴子搜索实验。我们展示了我们的设备是如何能够达到10个光子的频率为8 GHz的顺序的检测能力。第二种方法是基于由仅通过超导量子比特网络(SQN)耦合的两个谐振器形成的本征量子器件。这种方法依赖于谐振器光子的量子非破坏性测量。我们表明,注入RF功率到谐振器中,在传输系数(S21)的谐振下降的频率位置可以调制到4 MHz。我们预计,一旦优化,这两种设备都有可能达到单光子灵敏度。

英文摘要:

Axions detection requires the ultimate sensitivity down to the single photon limit. In the microwave region this corresponds to energies in the yJ range. This extreme sensitivity has to be combined with an extremely low dark count rate, since the probability of axions conversion into microwave photons is supposed to be very low. To face this complicated task, we followed two promising approaches that both rely on the use of superconducting devices based on the Josephson effect. The first one is to use a single Josephson junction (JJ) as a switching detector (i.e. exploiting the superconducting to normal state transition in presence of microwave photons). We designed a device composed of a coplanar waveguide terminated on a current biased Josephson junction. We tested its efficiency to pulsed (pulse duration 10 ns) microwave signals, since this configuration is closer to an actual axions search experiment. We show how our device is able to reach detection capability of the order of 10 photons with frequency 8 GHz. The second approach is based on an intrinsically quantum device formed by two resonators coupled only via a superconducting qubit network (SQN). This approach relies on quantum nondemolition measurements of the resonator photons. We show that injecting RF power into the resonator, the frequency position of the resonant drop in the transmission coefficient (S21) can be modulated up to 4 MHz. We anticipate that, once optimized, both the devices have the potential to reach single photon sensitivity.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑