HyperSLICE:用于低延迟交互式心脏检查的HyperBand优化螺旋轨迹
HyperSLICE: HyperBand optimized Spiral for Low-latency Interactive Cardiac Examination
AI总结:
本研究提出HyperSLICE框架,通过HyperBand优化可变密度螺旋采样轨迹并结合深度学习重建,实现了高时空分辨率和低延迟的交互式心脏磁共振成像。
摘要:
目的:交互式心脏磁共振成像用于快速扫描规划和MR引导介入。然而,实时采集和近实时可视化的要求限制了可实现的时空分辨率。本研究旨在通过优化欠采样螺旋采样并利用深度学习进行低延迟重建(深度伪影抑制)来提高交互式成像分辨率。方法:通过HyperBand对可变密度螺旋轨迹进行参数化和优化,以提供用于快速深度伪影抑制的最佳候选轨迹。训练数据由692次屏气CINE组成。所开发的交互式序列在模拟中进行了测试,并在13名受试者中进行了前瞻性测试(10名用于图像评估,2名在导管插入术期间,1名在运动期间)。在前瞻性研究中,优化的框架HyperSLICE在定量和定性图像指标方面与常规Cartesian实时成像和屏气CINE成像进行了比较。使用Friedman卡方检验和事后Nemenyi检验(p<0.05)检验了统计差异。结果:在模拟中,与径向和均匀螺旋采样相比,使用优化螺旋的NRMSE、pSNR、SSIM和LAPE均在统计学上显著更高,特别是在扫描计划改变后(SSIM:0.71 vs 0.45和0.43)。在前瞻性研究中,HyperSLICE实现了比常规Cartesian实时成像更高的空间和时间分辨率。该流程在导管回撤期间的患者中得到验证,表明重建速度足够快,适用于交互式成像。结论:HyperSLICE实现了高时空分辨率的交互式成像。与径向和均匀螺旋轨迹相比,优化螺旋采样实现了更好的整体图像质量和对图像转换的卓越处理。
英文摘要:
PURPOSE: Interactive cardiac magnetic resonance imaging is used for fast scan planning and MR guided interventions. However, the requirement for real-time acquisition and near real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework -HyperSLICE- was compared to conventional Cartesian real-time, and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post-hoc Nemenyi test (p<0.05). RESULTS: In simulations the NRMSE, pSNR, SSIM and LAPE were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (SSIM: 0.71 vs 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared to radial and uniform spiral trajectories.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。