关于基础计算流体动力学对左心房血流稳健可靠模型的重要性:是否有超出眼睛的东西?
On The Importance of Fundamental Computational Fluid Dynamics Towards a Robust and Reliable Model of Left Atrial Flows: Is There More Than Meets the Eye?
摘要:
左心房血流的计算流体动力学(CFD)研究已经达到了复杂的水平,例如,揭示了血液动力学和压力与心房颤动之间的合理关系。然而,很少有人关注LA流的基本流体建模。本研究的目的是调查的时空收敛,以及高(HR)与正常分辨率/精度(NR)的解决方案策略之间的差异,分别。通过使用二阶精度和空间/时间中心求解器,对从计算机断层成像扫描获得的12个患者特定左心房几何形状进行CFD模拟。会聚研究显示,左心房(LA)和左心耳(LAA)的时间平均壁面剪切应力(WSS)、振荡剪切指数(OSI)、相对停留时间(RRT)和内皮细胞激活电位(ECAP)的平均变异性分别约为30%和55%,即使在中间空间和时间分辨率之间也是如此。HR和NR模拟之间的比较显示,WSS、RRT和ECAP的LA具有良好的相关性(R^2 > 0.9),但OSI的相关性不高(R^2 = 0.63)。然而,除WSS(R^2 = 0.81)外,LAA的相关性较差,尤其是OSI、RRT和ECAP(R^2分别= 0.55、0.63和0.61)。这些误差与以前报道的疾病相关性的差异相当。为了稳健地预测心房血流动力学和应力,每个周期10 M个元素和10 k个时间步长的数值分辨率似乎是必要的(即,比空间和时间中通常使用的高一个数量级)。总之,注意基本的数值方面是至关重要的建立一个合理的,强大的,可靠的模型LA流量。
英文摘要:
Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, e.g., revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modelling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) versus normal-resolution/accuracy (NR) solution strategies, respectively. CFD simulations on 12 patient-specific left atrial geometries, obtained from computed tomography scans, were performed by using a second-order accurate and space/time centered solver. The convergence studies showed an average variability of around 30\% and 55\% for time averaged wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and endothelial cell activation potential (ECAP), even between intermediate spatial and temporal resolutions, in the left atrium (LA) and left atrial appendage (LAA), respectively. The comparison between HR and NR simulations showed good correlation in the LA for WSS, RRT, and ECAP (R^2 > 0.9), but not for OSI (R^2 = 0.63). However, there were poor correlations in the LAA especially for OSI, RRT, and ECAP (R^2 = 0.55, 0.63, and 0.61, respectively), except for WSS (R^2 = 0.81). The errors are comparable to differences previously reported with disease correlations. To robustly predict atrial hemodynamics and stresses, numerical resolutions of 10M elements and 10k time-steps per cycle seem necessary (i.e., one order of magnitude higher than normally used in both space and time). In conclusion, attention to fundamental numerical aspects is essential towards establishing a plausible, robust, and reliable model of LA flows.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。