arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2301.09523physics.acc-ph
收藏

用于HL-LHC的八台MQXFA低β四极磁体的制造、测试与分析中的挑战与经验总结

Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC

G. Ambrosio, K. Amm, M. Anerella, G. Apollinari, G. Arnau Izquierdo, M. Baldini, A. Ballarino, C. Barth, A. Ben Yahia, J. Blowers, P. Borges De Sousa, R. Bosser… 展开作者

G. Ambrosio, K. Amm, M. Anerella, G. Apollinari, G. Arnau Izquierdo, M. Baldini, A. Ballarino, C. Barth, A. Ben Yahia, J. Blowers, P. Borges De Sousa, R. Bossert, B. Bulat, R. Carcagno, D. W. Cheng, G. Chlachidze, L. Cooley, M. Crouvizier, A. Devred, J. DiMarco, S. Feher, P. Ferracin, J. Ferradas Troitino, L. Garcia Fajardo, S. Gourlay, H. M. Hocker, S. Izquierdo Bermudez, P. Joshi, S. Krave, E. M. Lee, J. Levitan, V. Lombardo, J. Lu, M. Marchevsky, V. Marinozzi, A. Moros, J. Muratore, M. Naus, F. Nobrega, T. Page, I. Pong, J. C. Perez, S. Prestemon, E. Ravaioli, K. L. Ray, G. Sabbi, J. Schmalzle, J. Seyl, S. Sgobba, S. Stoynev, T. Strauss, E. Todesco, D. Turrioni, G. Vallone, R. Van Weelderen, P. Wanderer, X. Wang, M. Yu

AI总结:

本文总结了美国HL-LHC加速器升级项目中8台MQXFA低β四极磁体的制造测试情况,分析了2台未达标磁体的限制机制,结合拆解经验修订装配规范,并通过有限元分析关联观测与测试性能。

摘要:

截至2022年10月底,美国高亮度大型强子对撞机(HL-LHC)加速器升级项目(AUP)已完成10台MQXFA磁体的制造,并对其中8台完成了测试。MQXFA磁体是将用于高亮度LHC(High Luminosity LHC)的Q1和Q3内三重态元件的低β四极磁体。本次AUP工作由布鲁克海文国家实验室(BNL)、费米实验室(Fermilab)和劳伦斯伯克利国家实验室(LBNL)共同承担,线材验证测试在国家高磁场实验室(NHMFL)开展。AUP质量保证计划的一个重要环节是在BNL的立式低温恒温器中对MQXFA磁体进行测试。首批4台量产磁体(MQXFA03-MQXFA06)全部满足可在BNL测试的验收标准。随后,2台磁体(MQXFA07和MQXFA08)未达到部分标准,已被拆解。在拆解MQXFA07过程中总结的经验推动了装配规范的修订,修订后的规范应用于MQXFA10及后续磁体的制造。本文总结了以下内容:1)所有MQXFA磁体的制造与测试数据;2)对MQXFA07/A08测试结果的分析及限制机制的表征;3)调查结果,包括MQXFA07拆解过程中获得的经验教训;4)将观测结果与测试性能关联起来的有限元分析。

英文摘要:

By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.