arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2301.09494q-bio.TOq-bio.CBq-bio.NCq-bio.QM
收藏

高密度磁肌电图在运动单元分解中优于高密度表面肌电图:一项仿真研究

High-density magnetomyography is superior to high-density surface electromyography for motor unit decomposition: a simulation study

Thomas Klotz, Lena Lehmann, Francesco Negro, Oliver Röhrle

AI总结:

本研究通过计算机仿真结合生物物理模型与分解算法,发现高密度磁肌电图(MMG)在识别运动单元放电模式上优于表面肌电图(EMG),可识别单元数增加76%,为无创研究神经肌肉系统提供了新方法。

摘要:

目的:研究运动单元对于理解运动控制、检测神经肌肉疾病以及控制人机接口至关重要。目前,个体运动单元的放电是通过在体分解肌电(EMG)信号来识别的。由于人体的物理特性和解剖结构,表面肌电图只能有限地分离个体运动单元。与电信号不同,磁场不会与人体组织发生相互作用。这一物理特性以及量子传感器的新兴技术,使得磁肌电图(MMG)成为一种极具前景的方法。然而,MMG在研究神经肌肉生理学方面的全部潜力尚未被探索。方法:在本研究中,我们进行了计算机模拟试验,将EMG和MMG的生物物理模型与最先进的运动单元分解算法相结合。这使得预测运动单元分解精度的上限成为可能。主要结果:结果表明,在稳健识别个体运动单元的放电模式方面,无创高密度MMG数据优于可比的高密度表面EMG数据。分解MMG而非EMG使可识别的运动单元数量增加了76%。值得注意的是,MMG在检测浅层运动单元时表现出较弱的偏差。意义:所提出的模拟为无创和在体研究神经系统提供了见解,这些方法通过其他手段难以实现。因此,本研究为开发新型生物医学技术提供了指导。

英文摘要:

Objective: Studying motor units (MUs) is essential for understanding motor control, the detection of neuromuscular disorders and the control of human-machine interfaces. Individual motor unit firings are currently identified in vivo by decomposing electromyographic (EMG) signals. Due to our body's properties and anatomy, individual motor units can only be separated to a limited extent with surface EMG. Unlike electrical signals, magnetic fields do not interact with human tissues. This physical property and the emerging technology of quantum sensors make magnetomyography (MMG) a highly promising methodology. However, the full potential of MMG to study neuromuscular physiology has not yet been explored. Approach: In this work, we perform in silico trials that combine a biophysical model of EMG and MMG with state-of-the-art algorithms for the decomposition of motor units. This allows the prediction of an upper-bound for the motor unit decomposition accuracy. Main results: It is shown that non-invasive high-density MMG data is superior over comparable high-density surface EMG data for the robust identification of the discharge patterns of individual motor units. Decomposing MMG instead of EMG increased the number of identifiable motor units by 76%. Notably, MMG exhibits a less pronounced bias to detect superficial motor units. Significance: The presented simulations provide insights into methods to study the neuromuscular system non-invasively and in vivo that would not be easily feasible by other means. Hence, this study provides guidance for the development of novel biomedical technologies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑