arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2301.08853cond-mat.str-elphysics.optics
收藏

解决Kagome金属CsV3Sb5在1550纳米波长下MOKE测量之间的矛盾

Resolving the discrepancy between MOKE measurements at 1550-nm wavelength on Kagome Metal CsV3Sb5

Jingyuan Wang, Camron Farhang, Brenden R. Ortiz, Stephen D. Wilson, Jing Xia

AI总结:

本文针对CsV3Sb5中自发MOKE信号是否存在的争议,利用两套最高9特斯拉训练场的Sagnac干涉仪系统测量,证明无论训练场大小和温度变化速率如何均无可观测自发MOKE信号,从而否定TRSB的光学证据。

摘要:

Kagome金属AV3Sb5(A = K、Cs、Rb)为研究相互交织的序提供了一个丰富的平台,例如电荷密度波(CDW)以及具有时间反演对称性破缺(TRSB)的手性序。早期关于大光学偏振旋转的报道曾被解释为磁光克尔效应(MOKE),并被视为TRSB的证据,但最近专门开展的光学旋转和MOKE实验已经澄清,这种大的光学旋转实际上来源于一种非常规的镜面旋转。然而,关于是否存在真正的自发MOKE信号,仍然存在一个关键矛盾:在最高0.3特斯拉的适度磁场训练后进行的实验中,在30纳弧度的噪声底以上未检测到MOKE信号,而在使用更高训练场的实验中则发现了微弧度级别的信号。这提出了一种有趣的可能性,即由于不同的磁历史,可能存在具有相反时间反演对称性性质的不同零场基态。为了明确确定CsV3Sb5中是否存在依赖于训练场的自发MOKE信号,我们使用两套Sagnac干涉仪装置进行了全面的MOKE测量,这两套装置能够提供最高9特斯拉的低训练场和高训练场,并对来自各种光学元件的信号贡献进行了仔细分析。我们得出结论:无论训练场的大小和温度升降速率如何,都不存在可观测的自发MOKE信号,因此没有TRSB的光学证据。

英文摘要:

Kagome metals AV3Sb5 (A = K, Cs, Rb) provide a rich platform for intertwined orders such as the charge density wave (CDW) and a chiral order with time-reversal symmetry breaking (TRSB). While early reports of large optical polarization rotations have been interpreted as the magneto-optic Kerr effect (MOKE) and as evidence for TRSB, recent dedicated optical rotation and MOKE experiments have clarified that this large optical rotation originates instead from an unconventional specular rotation. Yet a critical discrepancy remains regarding the possible existence of a true spontaneous MOKE signal: in experiments performed after training with modest magnetic fields of up to 0.3 Tesla, no MOKE signal was detected above the noise floor of 30 nano-radians, while micro-radian-level signals were found in an experiment using higher training fields. This raises an intriguing possibility of different zero-field ground states with opposite time-reversal symmetry properties, because of different magnetic histories. To unambiguously determine whether a training-field-dependent spontaneous MOKE signal exists in CsV3Sb5, we conduct comprehensive MOKE measurements with two Sagnac interferometer setups capable of both low and high training fields of up to 9 Tesla, and perform careful analyses of contributions of signals from various optical components. We conclude that there is no observable spontaneous MOKE signal, hence no optical evidence for TRSB, regardless of the magnitude of training fields and the speed of temperature ramping.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑