HQAlign:使用电流级建模对齐用于SV检测的纳米孔读数
HQAlign: Aligning nanopore reads for SV detection using current-level modeling
摘要:
动机:从样品DNA读数与参考基因组的比对中检测结构变体(SV)是理解人类疾病的重要问题。可以跨越重复区域的长读段以及这些长读段的准确比对在鉴定新SV中起重要作用。长读段测序仪如纳米孔测序可以通过提供非常长的读段但具有高错误率来解决这个问题,使得精确比对具有挑战性。由纳米孔测序引起的许多误差由于测序过程的物理性质而具有偏差,并且这些误差特性的适当利用可以在设计用于SV检测问题的稳健比对器中发挥重要作用。在本文中,我们设计和评估HQAlign,一种使用纳米孔测序读数进行SV检测的比对器。HQAlign的关键思想包括(i)使用基本的纳米孔读取以及纳米孔物理学来改善SV的比对(ii)将SV特异性变化并入比对流水线(iii)将这些调整到现有的最先进的长读取比对流水线minimap 2(v2.24)中,以进行有效的比对。结果如下:我们表明,HQAlign在不同的数据集上捕获了约4%-6%的互补SV,这些数据集被minimap 2比对所遗漏,同时对于真实的纳米孔读取数据,HQAlign具有与minimap 2相当的独立性能。对于HQAlign和minimap 2之间的常见SV调用,HQAlign提高了不同数据集上约10%-50%的SV的开始和结束断点准确度。此外,HQAlign将纳米孔读数比对的minimap 2比对率从85.64%提高到最近的端粒到端粒CHM 13组装的89.35%,并且将纳米孔读数比对的83.48%提高到GRCh 37人类基因组的86.65%。
英文摘要:
Motivation: Detection of structural variants (SV) from the alignment of sample DNA reads to the reference genome is an important problem in understanding human diseases. Long reads that can span repeat regions, along with an accurate alignment of these long reads play an important role in identifying novel SVs. Long read sequencers such as nanopore sequencing can address this problem by providing very long reads but with high error rates, making accurate alignment challenging. Many errors induced by nanopore sequencing have a bias because of the physics of the sequencing process and proper utilization of these error characteristics can play an important role in designing a robust aligner for SV detection problems. In this paper, we design and evaluate HQAlign, an aligner for SV detection using nanopore sequenced reads. The key ideas of HQAlign include (i) using basecalled nanopore reads along with the nanopore physics to improve alignments for SVs (ii) incorporating SV specific changes to the alignment pipeline (iii) adapting these into existing state-of-the-art long read aligner pipeline, minimap2 (v2.24), for efficient alignments. Results: We show that HQAlign captures about 4%-6% complementary SVs across different datasets which are missed by minimap2 alignments while having a standalone performance at par with minimap2 for real nanopore reads data. For the common SV calls between HQAlign and minimap2, HQAlign improves the start and the end breakpoint accuracy for about 10%-50% of SVs across different datasets. Moreover, HQAlign improves the alignment rate to 89.35% from minimap2 85.64% for nanopore reads alignment to recent telomere-to-telomere CHM13 assembly, and it improves to 86.65% from 83.48% for nanopore reads alignment to GRCh37 human genome.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。