arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2301.02607eess.SPcs.LGq-bio.QM
收藏

一种用于心电图去噪的数据驱动高斯过程滤波器

A Data-Driven Gaussian Process Filter for Electrocardiogram Denoising

Emory University(埃默里大学);Georgia Institute of Technology(佐治亚理工学院)

Mircea Dumitru, Qiao Li, Erick Andres Perez Alday, Ali Bahrami Rad, Gari D. Clifford, Reza Sameni

AI总结:

提出一种数据驱动的 GP 滤波器,利用 ECG 相位域简化计算并消除临时超参数,在 PhysioNet QT Database 上验证其在去噪和 QT 间期估计上优于小波基准滤波器。

摘要:

目的:基于高斯过程(GP)的滤波器已有效应用于包括心电图(ECG)滤波在内的多种场景,但其计算需求较高,且超参数的选择通常是临时的。方法:我们开发了一种数据驱动的 GP 滤波器来解决这两个问题,利用 ECG 相位域的概念——这是一种将 ECG 心拍时间规整到固定样本数并对齐 R 峰的表示方法,假定其服从高斯分布。在此假设下,样本均值和协方差的计算得以简化,实现了无需临时超参数的高效 GP 滤波器。该滤波器在 PhysioNet QT Database 上与最先进的基于小波的滤波器进行了评估比较。性能评估通过测量在 -5 至 30dB、步长 5dB 的 SNR 水平下使用加性噪声时的信噪比改善来进行。临床评估中,测量了原始与滤波信号 QT 间期估计值之间的误差,并与基准滤波器比较。结果:所提 GP 滤波器在所有测试噪声水平下均优于基准滤波器,在 QT 间期估计误差的偏差和方差上也优于最先进滤波器。结论:所提 GP 滤波器是用于临床与研究应用中 ECG 预处理的通用技术,适用于任意长度和采样频率的 ECG,并为其性能提供置信区间。

英文摘要:

Objective: Gaussian Processes (GP)-based filters, which have been effectively used for various applications including electrocardiogram (ECG) filtering can be computationally demanding and the choice of their hyperparameters is typically ad hoc. Methods: We develop a data-driven GP filter to address both issues, using the notion of the ECG phase domain -- a time-warped representation of the ECG beats onto a fixed number of samples and aligned R-peaks, which is assumed to follow a Gaussian distribution. Under this assumption, the computation of the sample mean and covariance matrix is simplified, enabling an efficient implementation of the GP filter in a data-driven manner, with no ad hoc hyperparameters. The proposed filter is evaluated and compared with a state-of-the-art wavelet-based filter, on the PhysioNet QT Database. The performance is evaluated by measuring the signal-to-noise ratio (SNR) improvement of the filter at SNR levels ranging from -5 to 30dB, in 5dB steps, using additive noise. For a clinical evaluation, the error between the estimated QT-intervals of the original and filtered signals is measured and compared with the benchmark filter. Results: It is shown that the proposed GP filter outperforms the benchmark filter for all the tested noise levels. It also outperforms the state-of-the-art filter in terms of QT-interval estimation error bias and variance. Conclusion: The proposed GP filter is a versatile technique for preprocessing the ECG in clinical and research applications, is applicable to ECG of arbitrary lengths and sampling frequencies, and provides confidence intervals for its performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑