新开发的环氧基等效组织适用于新生儿和5岁儿童的儿科放射学研究

Investigation of the aptness of newly developed epoxy-based equivalent tissues for newborn and 5-years old in paediatric radiology

Nabeel Ibrahim Ashour, Muhammad Fahmi Rizal Abdul Hadi, Nurul Ab. Aziz Hashikin, Mohammed Ali Dheyab, Ahmed Sadeq Musa, Nik Noor Ashikin Nik Ab Razak, Mohd Zahri Abdul Aziz

摘要:

组织等效(TE)材料的各种放射学应用包括质量检查、诊断成像和剂量评估。然而,儿科患者组织的代表性化合物在较低诊断光子能谱中用于科学用途的可用性有限。在本研究中,开发了几种TE替代品,可在这些能量范围内复制人体组织的射线照相特征,即用于新生儿软组织(ESST-NB)、新生儿骨骼组织(ESTB-NB)和代表5岁儿童的等效组织类型(分别为ESST和ESBT)的TE材料。ORNL程式化计算模型系列用作所需元素比例的来源。为开发的组织替代物计算的密度、有效原子序数、CT数和电子密度接近用作参考的体模系统的密度、有效原子序数、CT数和电子密度。此外,为了与材料选择和生产限制保持一致,所有材料都与质量密度、质量衰减系数和质量能量吸收系数的参考数据实现了尽可能密切的相关性。在47 keV至66 keV的能量范围内,新生儿的TE替代品与ORNL参考样本相比,μ/ \r{ho}的最大差异为1.6%至-3.01%,μ_en/ \r{ho}的最大差异为1.15%至-1.4%。代表5岁儿童的TE材料的相应等效数据范围为1.09%至-3.02%和1.92%至-2.53%。鉴于新构建的TE材料与参考数据之间的良好一致性,这些化合物随后可用于创建代表新生儿和5岁儿童组织类型的物理模型。

英文摘要:

The varied radiological applications of tissue equivalent (TE) materials encompass quality checks, diagnostic imaging and dose evaluations. Nevertheless, the availability of compounds representative of paediatric patient tissues for scientific use in lower diagnostic photon energy spectra is limited. In this study, several TE substitutes were developed which replicate the radiographic characteristics of human tissue within these energy ranges, i.e. TE materials for neonatal soft tissue (ESST-NB), neonatal skeletal tissue (ESTB-NB), and the equivalent tissue types representative of a 5 year old child (ESST and ESBT, respectively). The ORNL stylised computational model series was used as a source for the desired elemental proportions. The density, effective atomic number, CT numbers and electron densities calculated for the developed tissue substitutes approximated those of the phantom system used as a reference. Additionally, in keeping with the material choice and production limitations, as close correlations as possible were achieved for all the materials in relation to the reference data for mass densities, mass attenuation coefficients and mass energy-absorption coefficients. The TE substitutes for the newborn over an energy range of 47 keV to 66 keV exhibited maximum discrepancies for μ/\r{ho} of 1.6% to -3.01%, and for μ_en/\r{ho} of 1.15% to -1.4% in relation to the ORNL reference samples. The respective equivalent data ranges were 1.09 % to -3.02% and 1.92% to -2.53% for the TE materials representative of a 5-year-old. Given the excellent concordance achieved between the newly constructed TE materials and the reference data, these compounds can subsequently be utilised to create physical phantoms representative of tissue types in neonates and children aged 5 years.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑