arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2212.11273eess.SYcs.SY
收藏

一种用于高频睡眠相关振荡闭环神经调控的可穿戴脑电图系统

A Wearable EEG System for Closed-Loop Neuromodulation of High-Frequency Sleep-Related Oscillations

Scott Bressler, Ryan Neely, Heather Read, Ryan Yost, David Wang

AI总结:

本文提出一种可穿戴EEG闭环神经调控系统,通过设备端ecHT算法实现alpha振荡相位锁定听觉刺激,验证了其可行性并初步显示可缩短失眠症状者的睡眠起始潜伏期。

摘要:

在健康睡眠者中,皮层 alpha 振荡出现在从清醒到睡眠的过渡阶段,并在睡眠起始时消散。对于失眠个体,alpha 功率在清醒-睡眠过渡期间升高,并可能持续整夜。使用相位锁定刺激的神经调控技术已被提出作为改善慢波睡眠质量的药物替代方案。由于技术限制,该方法尚未在更快频率的 alpha 振荡上进行测试。本文研究了使用设备端实现的端点校正希尔伯特变换(ecHT)算法测量 alpha 相位并传递相位锁定听觉刺激以调控 alpha 并促进睡眠起始的可行性。首先,ecHT 算法在台式脑电图(EEG)设备上实现,并用于测量听觉诱发反应的时间及其在 alpha 振荡精确相位的传递。其次,一项初步的家庭研究测试了使用可穿戴版神经调控设备在 alpha(8-12 Hz)频率范围内进行实时相位锁定刺激的可行性。听觉刺激以高精度在 alpha 的预期相位传递,并且 alpha 振荡受到在相反相位传递的刺激的不同影响。我们的可穿戴系统能够测量 EEG 中存在的适合临床睡眠评分的睡眠微观和宏观事件。在刺激条件下,表现出睡眠起始失眠症状的一部分受试者的睡眠起始潜伏期缩短。本研究证明了使用可穿戴 EEG 设备对 alpha 振荡进行闭环跟踪和神经调控的可行性。初步结果表明,该方法可用于加速具有客观失眠症状个体的睡眠起始。

英文摘要:

In healthy sleepers, cortical alpha oscillations are present during the transition from wakefulness to sleep, and dissipate at sleep onset. For individuals with insomnia, alpha power is elevated during the wake-sleep transition and can persist throughout the night. Neuromodulation techniques using phase-locked stimulation have been put forth as alternatives to drugs for improving slow-wave sleep quality. Due to technical limitations, this approach has not been tested on faster frequency alpha oscillations. Here we examine the feasibility of using an endpoint-corrected version of the Hilbert Transform (ecHT) algorithm implemented on-device to measure alpha phase and deliver phase-locked auditory stimulation to modulate alpha and promote sleep initiation. First, the ecHT algorithm is implemented on a tabletop electroencephalogram (EEG) device and used to measure the timing of the auditory evoked response and its delivery at precise phases of the alpha oscillation. Secondly, a pilot at-home study tests feasibility to use a wearable version of the neuromodulation device for real-time phase-locked stimulation in the alpha (8-12 Hz) frequency range. Auditory stimulation was delivered at the intended phases of alpha with high precision, and alpha oscillations were affected differently by stimuli delivered at opposing phases. Our wearable system was capable of measuring sleep micro- and macro-events present in the EEG that were appropriate for clinical sleep scoring. Sleep onset latencies were reduced for a subset of subjects displaying sleep onset insomnia symptoms in the stimulation condition. This study demonstrates the feasibility of closed-loop tracking and neuromodulation of alpha oscillations using a wearable EEG device. Preliminary results suggest that this approach could be used to accelerate sleep initiation in individuals with objective insomnia symptoms.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑