arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2212.09075physics.ins-det
收藏

漂移管离子迁移谱仪的小型化设计

A Miniaturized Design of Drift Tube Ion Mobility Spectrometry

Ziyi Fang, Mang He

摘要:

漂移管离子迁移谱仪(DTIMS)是一种用于痕量化学物质检测的仪器,其小型化设计一直是工程实践中的迫切需求。在以往的研究中,在DTIMS的小型化设计中很少关注反应区。本文在反应区引入了一系列间距均匀的电极,实现了器件的小型化。研究发现,电极的加入扩大了TP快门前离子群的有效覆盖面积,提高了脉冲周期内进入漂移区的离子浓度,可以有效减小器件的整体尺寸。此外,本文还研究了电极厚度与电极间距(T/I)的比值对DTIMS的影响,并进行了优化,结果表明,尽管DTIMS体积较小,但适当的T/I比值可显著提高DTIMS的分辨率。制作了器件样机,与现有商用产品相比,DTIMS的尺寸减小了约50%,而测量分辨率提高了80%。

英文摘要:

The drift tube ion mobility spectrometry (DTIMS) is a device used to detect trace chemicals, and its miniaturized design is always desired in practice engineering. In previous studies, little attention has been paid to the reaction region of the DTIMS in the miniaturization design. In this letter, a series of electrodes with uniform interval is introduced in the reaction region to achieve miniaturization of the device. It is found that the added electrodes enlarge the effective coverage area of the ion swarms in front of the TP shutter and increase the concentration of ions entering the drift region within the pulse period, which can effectively reduce the overall size of the device. In addition, the effect of the thickness-to-interval (T/I) ratio of electrodes is investigated and optimized, and the resolution of the DTIMS is significantly improved with appropriate T/I ratio despite its compact size. The prototype of the device is fabricated, and the size of the DTIMS is reduced by about 50%, while the measured resolution is improved by 80% as compared with the existing commercial product.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑