A Data-driven Cognitive Salience Model for Objective Perceptual Audio Quality Assessment

Friedrich-Alexander Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡弗里德里希-亚历山大大学);Fraunhofer IIS(弗劳恩霍夫集成电路研究所)

Pablo M. Delgado, Jürgen Herre

英文摘要:

Objective audio quality measurement systems often use perceptual models to predict the subjective quality scores of processed signals, as reported in listening tests. Most systems map different metrics of perceived degradation into a single quality score predicting subjective quality. This requires a quality mapping stage that is informed by real listening test data using statistical learning (i.e., a data-driven approach) with distortion metrics as input features. However, the amount of reliable training data is limited in practice, and usually not sufficient for a comprehensive training of large learning models. Models of cognitive effects in objective systems can, however, improve the learning model. Specifically, considering the salience of certain distortion types, they provide additional features to the mapping stage that improve the learning process, especially for limited amounts of training data. We propose a novel data-driven salience model that informs the quality mapping stage by explicitly estimating the cognitive/degradation metric interactions using a salience measure. Systems incorporating the novel salience model are shown to outperform equivalent systems that only use statistical learning to combine cognitive and degradation metrics, as well as other well-known measurement systems, for a representative validation dataset.