利用磁共振成像同时测量燃料电池质子交换膜中的温度和水化

Simultaneous mapping of temperature and hydration in proton exchange membrane of fuel cells using magnetic resonance imaging

Darshan Chalise, Shreyan Majumdar, David G. Cahill

摘要:

质子交换膜(PEM)燃料电池的效率取决于质子在PEM中的迁移率,其由膜的水合作用和温度决定。虽然光学技术或中子或X射线散射技术可用于研究PEM中的水合和温度的不均匀性,但这些技术不能在测量分层PEM中提供三维空间分辨率。由于其提供非侵入性3D图像的能力,PEM中质子的自旋-晶格弛豫时间(T1)和自旋-自旋弛豫时间(T2)对比度磁共振成像(MRI)已被建议作为绘制燃料电池中水合的方法。我们表明,虽然T1和T2成像可用于映射质子交换膜在等温条件下的水化,质子T1和T2也是温度的函数。对于PEM燃料电池,其中电流密度大并且预期有热梯度,T1和T2弛豫时间不能用于映射水合。然而,移动质子的化学位移是水合作用的强函数,而不是温度。因此,化学位移成像(CSI)可以用来映射水合。可移动质子的扩散常数,这可以通过脉冲场梯度NMR确定,增加与温度和水合。因此,CSI之后通过脉冲场梯度的扩散成像可用于PEM中的水合和温度的单独映射。在这里,我们展示了Nafion PEM中水合作用和温度的16 x 16像素MRI映射,空间分辨率为1 mm x 1 mm,总扫描时间为3分钟,温度分辨率为6 K,水合作用的不确定性在15%以内。所展示的映射可以推广用于成像任何燃料电池或液流电池的交换膜。

英文摘要:

The efficiency of a proton exchange membrane (PEM) fuel cell depends on the mobility of protons in the PEM, which is determined by the hydration and temperature of the membrane. While optical techniques or neutron or x-ray scattering techniques may be used to study the inhomogeneities in hydration and temperature in PEMs, these techniques cannot provide 3 dimensional spatial resolution in measuring layered PEMs. Due to their ability to provide non-invasive 3D images, spin-lattice relaxation time (T1) and spin-spin relaxation time (T2) contrast magnetic resonance imaging (MRI) of protons in PEMs have been suggested as methods to map hydration in the fuel cells. We show that while T1 and T2 imaging may be used to map hydration in PEMs under isothermal conditions, proton T1 and T2 are also a function of temperature. For PEM fuel cells, where current densities are large and thermal gradients are expected, T1 and T2 relaxation times cannot be used for mapping hydration. The chemical shift of the mobile proton is, however, a strong function of hydration but not temperature. Therefore, chemical shift imaging (CSI) can be used to map hydration. The diffusion constant of the mobile proton, which can be determined by pulsed field gradient NMR, increases with both temperature and hydration. Therefore, CSI followed by imaging of diffusion via pulsed field gradients can be used for separate mappings of hydration and temperature in PEMs. Here, we demonstrate a 16 x 16 pixel MRI mapping of hydration and temperature in Nafion PEMs with a spatial resolution of 1 mm x 1 mm, a total scan time of 3 minutes, a temperature resolution of 6 K, and an uncertainty in hydration within 15%. The demonstrated mapping can be generalized for imaging exchange membranes of any fuel cells or flow batteries.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑